Tıp Fakültesi / Faculty of Medicine

Permanent URI for this collectionhttps://hdl.handle.net/11727/1403

Browse

Search Results

Now showing 1 - 2 of 2
  • Item
    Comparison of Helical and TomoDirect Techniques with Simultaneous Integrated Boost in Early Breast Cancer Patients
    (REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2023) Onal, Cem; Bozca, Recep; Oymak, Ezgi; Guler, Ozan Cem
    Background: The aim of the study was to perform dosimetric comparisons of helical (H) and TomoDirect (TD) plans for whole-breast irradiation (WBI) with simultaneous integrated boost (SIB) in early-stage breast cancer patients undergoing breast conserving surgery.Materials and methods: Fifty patients, 25 with left-side and 25 with right-side tumors, were determined for a treatment planning system for a total dose of 50.4Gy in 1.8Gy per fraction to WBI, with a SIB of 2.3Gy per fraction delivered to the tumor bed. The planning target volume (PTV) doses and the conformity (CI) and homogeneity indices (HI) for PTV(breast )and PTVboost, as well as organ-at-risk (OAR) doses and treatment times, were compared between the H and TD plans.Results: All plans met the PTV coverage criteria for the H plan, except for mean V107 of PTVbreast for TD plan. The H plan yielded better homogeneity and conformity of dose distribution compared to the TD plan. The ipsilateral mean lung doses were not significantly different between the two plans. The TD plans is advantageous for mean doses to the heart, contralateral breast and lung, spinal cord, and esophagus than the H plans. In both the H and TD plans, the right-sided breast patients had lower heart dose parameters than the left-sided breast patients. The TD plan is superior to the H plan in sparing the contralateral breast and lung by decreasing low-dose volumes.Conclusions: While the OAR dose advantages of TD are appealing, shorter treatment times or improved dose homogeneity and conformity for target volume may be advantageous for H plan.
  • Item
    Dosimetric Comparison of Sequential Versus Simultaneous-integrated Boost in Early-stage Breast Cancer Patients Treated With Breast-conserving Surgery
    (2019) Onal, Cem; Efe, Esma; Guler, Ozan C.; Yildirim, Berna A.; 0000-0001-6908-3412; 31662554; AAC-5654-2020
    Background/Aim: To compare simultaneous-integrated boost (SIB) versus sequential-boost (SB) delivered in the context of whole-breast irradiation (WBI) via volumetric-modulated arc therapy (VMAT) and helical-tomotherapy (HT). Materials and Methods: Planning target-volume (PTV) dosimetric parameters and organs at risk (OAR) were analyzed for SB plan (50 Gy plus 16 Gy boost) and SIB plan (50.4 Gy WBI and 64.4 Gy tumor bed boost) in VMAT and HT techniques. Results: Conformity and homogeneity for target-volume doses were better in HT plans compared to VMAT plans. There were no significant differences in ipsilateral lung doses between VMAT and HT plans for SB/SIB techniques, except for a significantly higher lung V5 value with VMAT-SB, and lung V13 value with HT-SIB technique. HT provided a statistically significant decrease in contralateral lung mean V5. Conclusion: The SIB technique showed better target-volume dose distribution in both HT and VMAT plans, and better sparing heart in HT compared to the SB technique.