Tıp Fakültesi / Faculty of Medicine

Permanent URI for this collectionhttps://hdl.handle.net/11727/1403

Browse

Search Results

Now showing 1 - 5 of 5
  • Item
    Prevalence of Persistent Median Artery in Carpal Tunnel Syndrome: Sonographic Assessment
    (2016) Altinkaya, Naime; Leblebici, Berrin; https://orcid.org/0000-0003-1348-8167; https://orcid.org/0000-0002-6241-268X; 26324380; AAM-5169-2021; AAM-3220-2021
    This study investigated the frequency of persistent median artery (PMA) in patients with carpal tunnel syndrome (CTS) and controls. A total of 84 CTS patient wrists, and 136 wrists of control subjects without CTS, were examined on ultrasonography (US) and color Doppler US (CDUS), and by electrophysiological evaluations. The frequency of PMA in CTS was evaluated. Of 84 CTS patient wrists, 2 (2.4 %) had a PMA (both on the right side). Of 136 control wrists, 12 (9 %) had a PMA, which was unilateral in eight (three right and five left), and bilateral in two, cases. There was no significant difference between the CTS patient and control groups with respect to the frequency of PMA (P > 0.05). There was no significant difference between the CTS patient and control groups in the frequency of PMA. We suggest that an ipsilateral PMA does not increase the risk of CTS.
  • Item
    Ultrasonographic and Electrophysiological Evaluation of the Ulnar Nerve in Patients Diagnosed With Carpal Tunnel Syndrome
    (2016) Ozlece, Hatice Kose; Huseyinoglu, Nergiz; Gok, Mustafa; Ilik, Faik; 27760070
    Purpose: In this study, we evaluated the ulnar nerve of patients diagnosed with carpal tunnel syndrome (CTS) using electrophysiology and ultrasonography. Methods: The study included 86 patients (136 hands) and 39 controls (78 hands) with normal electrophysiological assessment. According to Bland's classification, patients were divided into group 1 (grades 1-3 CTS) or group 2 (grades 4-6 CTS). The ulnar nerve was evaluated at the wrist using nerve conduction studies and ultrasonography. Results: The sensory velocity was slower in group 2 than in group 1 (P < 0.001), slower in group 2 than in controls (P < 0.001), and slower in group 1 than in controls (P < 0.005). Although the ultrasonography results showed a reduction in the ulnar nerve cross-sectional area in group 1 compared with controls, the difference was not statistically significant. However, the reduction was significant in group 2 compared with group 1 and controls (P < 0.001). Conclusions: Based on our study results, the ulnar nerve is affected electrophysiologically and morphologically in patients with CTS, especially those with advanced-stage CTS.
  • Item
    Is There A Correlation Between the Severity of Idiopathic Granulomatous Mastitis and Pre-Treatment Shear-Wave Elastography Findings? Original Research
    (2018) Aslan, Hulya; Arer, Ilker Murat; Pourbagher, Aysin; Ozen, Merve; 0000-0002-7138-246X; 30665211; AAK-9104-2021; HCH-8774-2022
    AIM: The aim of this study was to analyze the correlation between the severity of idiopathic Garulomatous Mastitis (IGM) and the pre-treatment Shear-Wave Elastography (SWE) findings. MATERIAL AND METHODS: A total of 39 patients diagnosed with granulomatous mastitis were included in the study between the dates of December 2014 and February 2017. The patients were divided into two groups. Group 1 was treated using a conservative protocol and steroids. Group 2 was treated surgically. Pre-treatment SWE findings of both groups were compared. RESULTS: The mean ages of the patients in group 1 and 2 were 38.44 +/- 9.6 and 3605 +/- 7.44 years, respectively. There were not any significant differences between the groups with regard to frequency of BI-BADS categories and Virtual touch tissue imaging (VTI) patterns. The mean Shear-Wave Spead (SWS) were 1.98 +/- 1.02 m/sec and 2.82 +/- 1.66 m/sec in group 1 and 2 respectively. The difference was not significant (p >= 0.05). The BI-RADS categories and VTI patterns did not show significant difference when the recurrent and non-recurrent patients were compared. CONCLUSION: There may not be a correlation with the pre-treatment SWE findings and severity of the IGM.
  • Item
    Efficacy of the Sonoelastography Method for Diagnosis of Fibrosis in Renal Transplant Patients
    (2022) Soudmand, Arash; Ozturk, Funda Ulu; Uslu, Nihal; Haberal, Nihan; Boyvat, Fatih; Moray, Gokhan; Haberal, Mehmet; https://orcid.org/0000-0002-3462-7632; 29993356; AAJ-8097-2021
    Objectives: Although biopsy is the most important method for diagnosing the cause of renal allograft dysfunction, sonoelastography, a new ultrasonography method, can be used to distinguish between the soft or hard nature of lesions. In this study, our aim was to investigate whether sonoelastography could diagnose fibrosis in renal transplant patients. Materials and Methods: In this prospective study, we included patients over 18 years old who were recommended for clinical biopsy. Sonoelastographic evaluation was made by conducting acoustic radiation force impulse measurements for each patient after they were admitted to the clinic for biopsy. Measurements were performed just before the biopsy procedure. All results were examined by 2 experienced radiologists using the Siemens S3000 Ultrasound Machine (Erlangen, Germany). Comparisons of ultrasonographic values with biopsy results were made with SPSS software (SPSS: An IBM Company, version 20, IBM Corporation, Armonk, NY, USA). Results: Of the 65 patients included in this study, pathology showed acute T-cell-mediated rejection in 37 patients. There was a significant correlation between the pathologic Banff scores and the sonographic acoustic radiation force impulse values (P = .002), where the degree of Banff increased as the mean acoustic radiation force impulse values elevated. A rise in mean impulse values correlated with increased degree of interstitial fibrosis in renal allografts. Renal parenchymal echogenicity of patients significantly differed by sex (P = .009), with an average renal echogenicity of grade 1 in women and grade 0 in men. Also, a statistically significant difference was found between age of the renal transplant recipient and resistive index values. Conclusions: Our study showed a significant correlation between Banff degree and the acoustic radiation force impulse values of renal transplant patients. In addition to biopsy, sonoelastography can be beneficial for the diagnosis of fibrosis in renal transplant patients.
  • Item
    Liver Stiffness Measurements Using Acoustic Radiation Force Impulse in Recipients of Living-Donor and Deceased-Donor Orthotopic Liver Transplant
    (2021) Haberal, Kemal Murat; Turnaoglu, Hale; Ozdemir, Adnan; Uslu, Nihal; Reyhan, Asuman Nihan Haberal; Moray, Gokhan; Haberal, Mehmet; 0000-0002-8211-4065; 0000-0002-3462-7632; 28836931; R-9398-2019; AAJ-8097-2021
    Objectives: The aim of this study was to evaluate the diagnostic efficiency of the acoustic radiation force impulse (Siemens Medical Solutions, Erlangen, Germany) elastography in assessment of fibrosis in orthotopic liver transplant patients. Materials and Methods: We enrolled 28 orthotopic liver transplant patients (5 deceased and 23 living donors), whose biopsy decision had been prospectively given clinically. Ten acoustic radiation force impulse elastographic measurements were applied before the biopsy or within 3 days after the biopsy by 2 radiologists. After the core tissue needle biopsy, specimens of all patients were analyzed according to the modified Ishak scoring system. Measurements of acoustic radiation force impulse elastography and pathology specimen results were compared. Results: From 28 biopsies, fibrosis scores of 4 biopsies were evaluated as F0 (14.3%), 16 as F1 (57.1%), 4 as F2 (14.3%), and 4 as F3 (14.3%). Mean results of acoustic radiation force impulse measurements were calculated as 1.4 +/- 0.07 in F0, 1.74 +/- 0.57 in F1, 2.19 +/- 0.7 in F2, and 2.18 +/- 0.35 in F3. There were no significant correlations of mean acoustic radiation force impulse values between the F0 versus F1 (P =.956) and F0 versus F2 stages (P =.234). A statistically significant correlation of mean acoustic radiation force impulse values was found between the F0 and F3 fibrosis stages (P =.046). Conclusions: Acoustic radiation force impulse imaging is a promising screening test for detecting significant liver fibrosis (>= F3 in modified Ishak) in living- donor or deceased-donor orthotopic liver transplant recipients.