Tıp Fakültesi / Faculty of Medicine
Permanent URI for this collectionhttps://hdl.handle.net/11727/1403
Browse
2 results
Search Results
Item Three-Dimensional Right Ventricular Strain Versus Volume Quantification in Heart Transplant Recipients in Relation to Pulmonary Artery Pressure(2017) Sade, Leyla Elif; Kozan, Hatice; Eroglu, Serpil; Pirat, Bahar; Aydinalp, Alp; Sezgin, Atilla; Muderrisoglu, Haldun; 0000-0003-3737-8595; 0000-0003-4576-8630; 0000-0002-9635-6313; 0000-0002-3761-8782; 0000-0003-3055-7953; 28260474; ABG-1582-2021; AAQ-7583-2021; AAI-8897-2021; AAG-8233-2020; AAD-5841-2021Objectives: Residual pulmonary hypertension challenges the right ventricular function and worsens the prognosis in heart transplant recipients. The complex geometry of the right ventricle complicates estimation of its function with conventional transthoracic echo cardiography. We evaluated right ventricular function in heart transplant recipients with the use of 3-dimensional echocardiography in relation to systolic pulmonary artery pressure. Materials and Methods: We performed 32 studies in 26 heart transplant patients, with 6 patients having 2 studies at different time points with different pressures and thus included. Right atrial volume, tricuspid annular plane systolic excursion, peak systolic annular velocity, fractional area change, and 2-dimensional speckle tracking longitudinal strain were obtained by 2-dimensional and tissue Doppler imaging. Three-dimensional right ventricular volumes, ejection fraction, and 3-dimensional right ventricular strain were obtained from the 3-dimensional data set by echocardiographers. Systolic pulmonary artery pressure was obtained during right heart catheterization. Results: Overall mean systolic pulmonary artery pressure was 26 +/- 7 mm Hg (range, 14-44 mmHg). Three-dimensional end-diastolic (r = 0.75; P <.001) and end-systolic volumes (r = 0.55; P = .001) correlated well with systolic pulmonary artery pressure. Right ventricular ejection fraction and right atrium volume also significantly correlated with systolic pulmonary artery pressure (r = 0.49 and P = .01 for both). However, right ventricular 2-and 3-dimensional strain, tricuspid annular plane systolic excursion, and tricuspid annular velocity did not. Conclusions: The effects of pulmonary hemodynamic burden on right ventricular function are better estimated by a 3-dimensional volume evaluation than with 3-dimensional longitudinal strain and other 2-dimensional and tissue Doppler measurements. These results suggest that the peculiar anatomy of the right ventricle necessitates 3-dimensional volume quantification in heart transplant recipients in relation to residual pulmonary hypertension.Item Subclinical myocardial dysfunction in liver transplant candidates determined using speckle-tracking imaging(2019) Inci, Saadet Demirtas; Sade, Leyla Elif; Altin, Cihan; Pirat, Bahar; Pamukcu, Hilal Erken; Yilmaz, Sabriye; Muderrisoglu, Haldun; 31802775Objective: There are various cardiovascular abnormalities in end-stage liver disease (ESLD). In these patients, left ventricular (LV) systolic function is normal at rest but deteriorates during stress. This deterioration may be due to subclinical myocardial dysfunction. This study evaluated global LV and right ventricular (RV) functions using 2-dimensional (2D) speckle tracking in patients with ESLD. Methods: Forty liver transplant candidates with ESLD and 26 healthy individuals were included in the study. All of the patients underwent conventional echocardiographic measurement. Longitudinal, circumferential, and radial strain measurements, as well as apical and parasternal short-axis image recordings were obtained. All 2D strain measurements were measured with offline analysis using velocity vector imaging (VVI) software. Results: In the apical 4- and 2-chamber measurements, the LV mean longitudinal strain was significantly lower in the patient group compared with that of the control group (-16.0 +/- 3.2% versus -17.6 +/- 2.2%, -16.7 +/- 3.3% versus -18.7 +/- 2.1 +/- 2.1 %; p=0.002, respectively). The LV mean circumferential strain did not differ between groups. The LV mean radial strain and RV longitudinal strain were significantly lower in the patient group (45.4 +/- 10.7 vs. 52.7 +/- 10.8%; p=0.01 and -19.2 +/- 3.5% versus -21.5 +/- 3.6%; p=0.03, respectively). Conclusions: Subclinical impairment of global LV and RV systolic functions was determined in liver transplantation candidates using VVI. This deterioration was detected in longitudinal and radial deformation rather than circumferential deformation mechanics, which is consistent with early-stage LV myocardial dysfunction.