Optimization Of Patient-Based Real-Time Quality Control Based On The Youden Index

dc.contributor.authorTopcu, Deniz Ilhan
dc.contributor.authorCubukcu, Hikmet Can
dc.contributor.pubmedID35810801en_US
dc.date.accessioned2022-12-21T08:00:59Z
dc.date.available2022-12-21T08:00:59Z
dc.date.issued2022
dc.description.abstractAim: This study sets out to investigate the utility of exponentially weighted moving average (EWMA) as patient-based real-time quality control (PBRTQC) by conducting a simulation study and subsequent real-patient data implementation to determine optimal EWMA features (weighting factors, control limits, and truncation methods) based on the Youden index. Methods: A simulation experiment was conducted in the first stage to investigate optimal EWMA features for the tests, including aspartate aminotransferase, blood urea nitrogen, and glucose, calcium, creatinine, potassium, sodium, triglycerides, thyroid - stimulating hormone (TSH), and vitamin B12 tests. In the second stage of the study, EWMA was applied to real patient data to elucidate practical utility and achieve final optimal EWMA features. Different degrees of systematic errors (SE) including total allowable error (TEa) as a maximum error level were added to both simulation and patient results, and then the EWMA performance was assessed for different EWMA features. We calculated Youden's index for each combination of EWMA features to find their optimal features to achieve minimum false positive rate (FPR) and maximum error detection rate at the SE level corresponding to TEa. Results: EWMA implementation on real patient data revealed optimal EWMA features for each test. FPR values of creatinine and glucose were 18.48% and 10.17%, respectively, which exceeded the acceptable criteria for FPR (10%). The remaining six analytes showed acceptable FPR. Conclusions: We showed the implementation of EWMA as PBRTQC, and optimization of its features based on the Youden index by conducting extensive performance evaluations and simulations in this study.en_US
dc.identifier.issn0009-8981en_US
dc.identifier.issue50en_US
dc.identifier.scopus2-s2.0-85134317245en_US
dc.identifier.startpage56en_US
dc.identifier.urihttp://hdl.handle.net/11727/8391
dc.identifier.volume534en_US
dc.identifier.wos000830894000003en_US
dc.language.isoengen_US
dc.relation.isversionof10.1016/j.cca.2022.06.028en_US
dc.relation.journalCLINICA CHIMICA ACTAen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergien_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectQuality controlen_US
dc.subjectQuality managementen_US
dc.subjectYouden indexen_US
dc.subjectPatient based real time quality controlen_US
dc.subjectExponentially weighted moving averageen_US
dc.subjectEWMAen_US
dc.titleOptimization Of Patient-Based Real-Time Quality Control Based On The Youden Indexen_US
dc.typearticleen_US