Thorax CT Dose Reduction Based on Patient Features: Effect of Patient Characteristics on Image Quality and Effective Dose

dc.contributor.authorKoc, Gizem Gul
dc.contributor.authorKoc, Zafer
dc.contributor.authorKaniyev, Tahir
dc.contributor.authorKokangul, Ali
dc.contributor.orcIDhttps://orcid.org/0000-0003-0987-1980en_US
dc.contributor.pubmedID30908322en_US
dc.contributor.researcherIDS-8384-2016en_US
dc.date.accessioned2023-09-07T10:08:33Z
dc.date.available2023-09-07T10:08:33Z
dc.date.issued2019
dc.description.abstractComputed tomography (CT) radiation dose reduction is vital without compromising image quality. The aim was to determine the effects of patient characteristics on the received radiation dose and image quality in chest CT examinations and to be able to predict dose and image quality prior to scanning. Consecutive 230 patients underwent routine chest CT examinations were included. CT examination and patients input parameters were recorded for each patient. The effect of patients' demographics/anthropometrics on received dose and image quality was investigated by linear regression analysis. All parameters were evaluated using an artificial neural network (ANN). Of all parameters, patient demographics/anthropometrics were found to be 98% effective in calculating dose reduction. Using ANN on 60 new patients was more than 90% accurate for output parameters and 91% for image quality. Patient characteristics have a significant impact on radiation dose and image quality. Dose and image quality can be determined before CT. This will allow setting the most appropriate scanning parameters before the CT scan.en_US
dc.identifier.endpage745en_US
dc.identifier.issn0017-9078en_US
dc.identifier.issue5en_US
dc.identifier.scopus2-s2.0-85063713199en_US
dc.identifier.startpage736en_US
dc.identifier.urihttp://hdl.handle.net/11727/10518
dc.identifier.volume116en_US
dc.identifier.wos000463601000020en_US
dc.language.isoengen_US
dc.relation.isversionof10.1097/HP.0000000000001008en_US
dc.relation.journalHEALTH PHYSICSen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergien_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectoperational topicsen_US
dc.subjectcomputed tomographyen_US
dc.subjectdoseen_US
dc.subjectlowen_US
dc.subjectradiation doseen_US
dc.titleThorax CT Dose Reduction Based on Patient Features: Effect of Patient Characteristics on Image Quality and Effective Doseen_US
dc.typearticleen_US

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: