Short-Term Results of Neurelec Digisonic SP Cochlear Implantation in Prelingually Deafened Children

dc.contributor.authorSenkal, Ozgul Akin
dc.contributor.authorHizal, Evren
dc.contributor.authorYavuz, Haluk
dc.contributor.authorYilmaz, Ismail
dc.contributor.authorOzluoglu, Levent Naci
dc.contributor.orcIDhttps://orcid.org/0000-0002-3554-8274en_US
dc.contributor.orcIDhttps://orcid.org/0000-0002-9699-6783en_US
dc.contributor.orcIDhttps://orcid.org/0000-0003-3320-204Xen_US
dc.contributor.orcIDhttps://orcid.org/0000-0002-1694-7608en_US
dc.contributor.orcIDhttps://orcid.org/0000-0002-2150-0237en_US
dc.contributor.pubmedID23749057en_US
dc.contributor.researcherIDF-9493-2013en_US
dc.contributor.researcherIDA-5853-2018en_US
dc.contributor.researcherIDF-6315-2015en_US
dc.contributor.researcherIDAAJ-2992-2021en_US
dc.contributor.researcherIDAAI-8020-2021en_US
dc.date.accessioned2024-02-27T12:27:02Z
dc.date.available2024-02-27T12:27:02Z
dc.date.issued2014
dc.description.abstractThis paper examines the reports on the selection criteria and the post-operative performance of 25 children implanted with the Neurelec Digisonic SP. This study reported benefits from Neurelec Digisonic SP cochlear implant in auditory and speech perception outcomes. There has been a lack of studies into the additional factors such as level of the mothers' education and bilingualism, which is a factor that may have a significant effect on the success of cochlear implantation. This paper examines the reports on the reasons for the differences in performance and the post-operative performance of 25 children implanted with the Neurelec Digisonic SP. Meaningful Auditory Integration Scale and Meaningful Use of Speech Scale questionnaires were used just before 3, 6, 12, and 18 months following implantation. Electrode array was inserted without difficulty in all cases, with no complications to date. This is a retrospective and cross-sectional study and all the data were collected between March 2010 and December 2012. Auditory performance improved over time for up to 12 months after implantation. Our experience indicates that the Neurelec Digisonic SP cochlear implant system in children under the age of two is relatively safe and reliable. The Neurelec Digisonic SP device surgery can be performed without complications. Auditory performance results support the effectiveness of early implantation. These important findings further support the importance of professionals working very closely with parents or especially mothers and enhancing their involvement in achieving therapy goals to develop auditory skills and speech in young children following cochlear implantation.en_US
dc.identifier.endpage1422en_US
dc.identifier.issn0937-4477en_US
dc.identifier.issue6en_US
dc.identifier.scopus2-s2.0-84902257982en_US
dc.identifier.startpage1415en_US
dc.identifier.urihttp://hdl.handle.net/11727/11660
dc.identifier.volume271en_US
dc.identifier.wos000335782000012en_US
dc.language.isoengen_US
dc.relation.isversionof10.1007/s00405-013-2576-zen_US
dc.relation.journalEUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergien_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCochlear implantsen_US
dc.subjectHearingen_US
dc.subjectAuditory perceptionen_US
dc.subjectMotheren_US
dc.subjectEducationen_US
dc.subjectBilingualismen_US
dc.subjectChilden_US
dc.titleShort-Term Results of Neurelec Digisonic SP Cochlear Implantation in Prelingually Deafened Childrenen_US
dc.typeArticleen_US

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: