Comparison of Keratometric Measurements Obtained by the Verion Image Guided System with Optical Biometry and Auto-Keratorefractometer

dc.contributor.authorAsena, Leyla
dc.contributor.authorGungor, Sirel Gur
dc.contributor.authorAkman, Ahmet
dc.contributor.orcID0000-0002-6848-203Xen_US
dc.contributor.orcID0000-0001-6178-8362en_US
dc.contributor.pubmedID27271763en_US
dc.contributor.researcherIDE-5914-2016en_US
dc.contributor.researcherIDAAD-5967-2021en_US
dc.date.accessioned2023-07-21T08:22:57Z
dc.date.available2023-07-21T08:22:57Z
dc.date.issued2017
dc.description.abstractThe aim of this study was to compare the keratometric measurements of Verion Image Guided System with an optical biometer (Zeiss IOLMaster 500, Carl Zeiss Meditec, Jena, Germany) and an automated keratorefractometer (AKR) (Topcon KR-8900, Topcon, Japan). In this prospective clinical trial, the right eyes of 52 patients with cataract were examined (mean age 62.25 +/- 12.16 years). The measurements were taken by the three systems in a random order. Keratometric data, magnitude of astigmatism, and astigmatic axis measurements from all three instruments were compared. The results were evaluated using, intraclass correlation coefficients (ICC), Bland-Altman plots, and paired samples t tests. The mean flat/steep K of Verion, IOLMaster, and AKR were 43.22 +/- 1.38D/44.23 +/- 1.46D, 43.07 +/- 1.26D/44.05 +/- 1.34D, and 43.07 +/- 1.31D/43.89 +/- 1.42D, respectively. Flat K readings of Verion were higher than IOLMaster and AKR (p < 0.05 for both). Steep K readings were different for all three (p < 0.05). The magnitude of astigmatism by Verion and IOLMaster were 0.98 +/- 0.65D and 0.98 +/- 0.59D (p = 0.88). The mean astigmatism measured by the AKR was 0.82 +/- 0.62D, less than the other two instruments (p < 0.001). Astigmatic axis measurements of Verion and AKR differed < 10A degrees in 38, between 10A degrees and 20A degrees in 5, and > 20A degrees in 9 eyes; the same difference was 30, 11, and 11 eyes, respectively, between Verion and IOLMaster. Although, keratometric and astigmatic results obtained from Verion were not completely interchangeable with IOLMaster and AKR, especially the agreement between Verion and IOLMaster was excellent with ICCs close to one. However, there were pronounced astigmatic axis measurement differences between three instruments.en_US
dc.identifier.eissn1573-2630en_US
dc.identifier.endpage399en_US
dc.identifier.issn0165-5701en_US
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-84976313567en_US
dc.identifier.startpage391en_US
dc.identifier.urihttp://hdl.handle.net/11727/10036
dc.identifier.volume37en_US
dc.identifier.wos000397597900013en_US
dc.language.isoengen_US
dc.relation.isversionof10.1007/s10792-016-0274-8en_US
dc.relation.journalINTERNATIONAL OPHTHALMOLOGYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergien_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAstigmatismen_US
dc.subjectBiometryen_US
dc.subjectKeratometryen_US
dc.subjectVerion Image Guided Systemen_US
dc.titleComparison of Keratometric Measurements Obtained by the Verion Image Guided System with Optical Biometry and Auto-Keratorefractometeren_US
dc.typeArticleen_US