Comparative Analysis of Different Periapical Index Systems Used in Cone-Beam Computed Tomography

dc.contributor.authorSisli, Selen Nihal
dc.contributor.authorYilmaz, Busra
dc.contributor.authorOzpolat, Zeynep
dc.contributor.authorGulsahi, Kamran
dc.contributor.orcID0000-0003-0633-5648en_US
dc.contributor.orcID0000-0003-3510-7265en_US
dc.contributor.pubmedID33547741en_US
dc.contributor.researcherIDAAX-5565-2021en_US
dc.date.accessioned2022-09-16T11:20:12Z
dc.date.available2022-09-16T11:20:12Z
dc.date.issued2021
dc.description.abstractThis study aimed to compare the three index systems designed for cone-beam computed tomography (CBCT) in terms of intra- and inter-observer agreement. 117 root-filled teeth with or without periapical radiolucency from 77 of already existing CBCT images were chosen randomly. Two observers evaluated the periapical status of the selected teeth and graded the scores twice using CBCT periapical index (CBCTPAI), endodontic radiolucency index (ERI) and complex periapical index (COPI) part of the periapical and endodontic status scale (PESS), respectively. The researchers' self-agreement kappa values ranged from substantial to almost perfect. A moderate inter-observer agreement was present for the COPI and ERI, whereas a fair agreement was present for CBCTPAI. The researchers' ICC for the inter-observer reliability of CBCTPAI, ERI and COPI was 0.75, 0.77 and 0.80, respectively. COPI had the highest self-agreement and inter-observer reliability. ERI showed the highest intra-observer variation, whereas CBCTPAI showed the highest inter-observer variation.en_US
dc.identifier.endpage407en_US
dc.identifier.issn1329-1947en_US
dc.identifier.issue3en_US
dc.identifier.scopus2-s2.0-85100532678en_US
dc.identifier.startpage401en_US
dc.identifier.urihttp://hdl.handle.net/11727/7807
dc.identifier.volume47en_US
dc.identifier.wos000615193600001en_US
dc.language.isoengen_US
dc.relation.isversionof10.1111/aej.12486en_US
dc.relation.journalAUSTRALIAN ENDODONTIC JOURNALen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergien_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectconeen_US
dc.subjectbeam computed tomographyen_US
dc.subjectendodonticsen_US
dc.subjectperiapical indexen_US
dc.titleComparative Analysis of Different Periapical Index Systems Used in Cone-Beam Computed Tomographyen_US
dc.typearticleen_US

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: