Effect of using pump on postoperative pleural effusion in the patients that underwent CABG

dc.contributor.authorOzulku, Mehmet
dc.contributor.authorAygun, Fatih
dc.contributor.pubmedID27163421en_US
dc.date.accessioned2019-09-30T11:38:41Z
dc.date.available2019-09-30T11:38:41Z
dc.date.issued2015
dc.description.abstractObjective: The present study investigated effect of using pump on postoperative pleural effusion in patients who underwent coronary artery bypass grafting. Methods: A total of 256 patients who underwent isolated coronary artery bypass grafting surgery in the Cardiovascular Surgery clinic were enrolled in the study. Jostra-Cobe (Model 043213 105, VLC 865, Sweden) heart-lung machine was used in on-pump coronary artery bypass grafting. Off-pump coronary artery bypass grafting was performed using Octopus and Starfish. Proximal anastomoses to the aorta in both on-pump and off-pump techniques were performed by side clamps. The patients were discharged from the hospital between postoperative day 6 and day 11. Results: The incidence of postoperative right pleural effusion and bilateral pleural effusion was found to be higher as a count in Group 1 (on-pump) as compared to Group 2 (off-pump). But the difference was not statistically significant [P>0.05 for right pleural effusion (P=0.893), P>0.05 for bilateral pleural effusion (P=0.780)]. Left pleural effusion was encountered to be lower in Group 2 (off-pump). The difference was found to be statistically significant (P<0.05, P=0.006). Conclusion: Under the light of these results, it can be said that left pleural effusion is less prevalent in the patients that underwent off-pump coronary artery bypass grafting when compared to the patients that underwent on-pump coronary artery bypass grafting.en_US
dc.identifier.endpage473en_US
dc.identifier.issn0102-7638
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-84945900227en_US
dc.identifier.startpage466en_US
dc.identifier.urihttp://www.scielo.br/scielo.php?pid=S0102-76382015000400010&script=sci_arttext
dc.identifier.urihttp://hdl.handle.net/11727/4017
dc.identifier.volume30en_US
dc.identifier.wos000364808300010en_US
dc.language.isoengen_US
dc.relation.isversionof10.5935/1678-9741.20150029en_US
dc.relation.journalREVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULARen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCoronary Artery Diseaseen_US
dc.subjectCardiac Surgical Proceduresen_US
dc.subjectCardiopulmonary Bypassen_US
dc.subjectPleural Effusionen_US
dc.subjectCoronary Artery Bypassen_US
dc.subjectOff-Pumpen_US
dc.titleEffect of using pump on postoperative pleural effusion in the patients that underwent CABGen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
0102-7638-rbccv-30-04-0466.pdf
Size:
479.21 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: