A Comparision of Axillary with Infrared Tympanic and Non-Contact Infrared Thermometry

dc.contributor.authorCoban, Bayram
dc.contributor.authorDolgun, Anil
dc.contributor.orcID0000-0002-2693-0666en_US
dc.contributor.researcherIDD-4235-2013en_US
dc.date.accessioned2023-06-22T12:40:06Z
dc.date.available2023-06-22T12:40:06Z
dc.date.issued2016
dc.description.abstractObjective: Ideally, the temperature measurement should be safe, easy, noninvasive, cost effective, time efficient and technique independent and should precisely reflect core body temperature and should not be influenced by the environmental temperature. In our study, we compared the axillary digital with infrared tympanic and forehead non-contact infrared measurement. Material and Methods: Axillary digital, tympanic infrared and non-contact forehead measurements were taken simultaneously with devices used in hospital routinely. Results: Temperature was measured for 276 patients between 0 and 14 years old. Infrared tympanic measurements were significantly higher than axillary (p<0.001) and non-contact infrared measurements (p<0.001). There was no difference between axillary and forehead measurements (p=0.999). Feverish patients who measured by axillary method was not detected in 11.6% of tympanic and 41.9% of non-contact forehead measurements. Conclusion: Tympanic infrared measurements are higher than axillary digital and non-contact infrared measurements. Temperature measurement must be reassured with other techniques in case of any doubt.en_US
dc.identifier.eissn1308-5271en_US
dc.identifier.endpage85en_US
dc.identifier.issn1307-1068en_US
dc.identifier.issue3en_US
dc.identifier.scopus2-s2.0-84994494340en_US
dc.identifier.startpage82en_US
dc.identifier.urihttp://hdl.handle.net/11727/9806
dc.identifier.volume10en_US
dc.identifier.wos000388244300001en_US
dc.language.isoturen_US
dc.relation.isversionof10.5152/ced.2016.2417en_US
dc.relation.journalJOURNAL OF PEDIATRIC INFECTIONen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergien_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectChildrenen_US
dc.subjecttemperature measurementen_US
dc.subjecttympanic membraneen_US
dc.subjectinfrareden_US
dc.subjectaxillaryen_US
dc.titleA Comparision of Axillary with Infrared Tympanic and Non-Contact Infrared Thermometryen_US
dc.typearticleen_US

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: