Which Sequence Should Be Used in the Thorax Magnetic Resonance Imaging of COVID-19: A Comparative Study

dc.contributor.authorAtes, Ayse sule
dc.contributor.authorYagdiran, Burak
dc.contributor.authorTaydas, Onur
dc.contributor.authorFaruk Ates, Omer
dc.date.accessioned2024-05-06T10:12:50Z
dc.date.available2024-05-06T10:12:50Z
dc.date.issued2023
dc.description.abstractBackground and aim: To evaluate and compare magnetic resonance imaging (MRI) sequences that could potentially be used in the diagnosis of coronavirus disease 2019 (COVID-19). Materials and methods: Included in the study were 42 patient who underwent thorax computed tomography (CT) for COVID-19 pneumonia and thorax MRI for any reason within 24 h after CT. The T2-weighted fast spin echo periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (T2W-FSE-P), fast imaging employing steady-state acquisition, T2 fat-saturated FSE, axial T1 liver acquisition with volume acceleration (LAVA) and single-shot FSE images were compared in terms of their ability to show COVID-19 findings. Results: The mean age of the patients was 47.2 +/- 24 years. Of the patients, 22 were male (52.4%) and 20 (47.6%) were female. The interobserver intraclass coefficient (ICC) for the image quality score was the highest in the T2W-FSE-P sequence and lowest in the T1 LAVA sequence. All of the lesion-based evaluations of the interobserver agreement were statistically significant, with the kappa value varying between 0.798 and 0.998. Conclusion: All 5 sequences evaluated in the study were successful in showing the parenchymal findings of COVID-19. Since the T2W-FSE-P sequence had the best scores in both interobserver agreement and ICC for the image quality score, it was considered that it can be included in thorax MRI examinations to assist the diagnosis of COVID-19.en_US
dc.identifier.eissn1303-6165en_US
dc.identifier.endpage1223en_US
dc.identifier.issn1300-0144en_US
dc.identifier.issue5en_US
dc.identifier.scopus2-s2.0-85175568791en_US
dc.identifier.startpage1214en_US
dc.identifier.urihttps://journals.tubitak.gov.tr/cgi/viewcontent.cgi?article=5686&context=medical
dc.identifier.urihttp://hdl.handle.net/11727/12053
dc.identifier.volume53en_US
dc.identifier.wos001108669900029en_US
dc.language.isoengen_US
dc.relation.isversionof10.55730/1300-0144.5687en_US
dc.relation.journalTURKISH JOURNAL OF MEDICAL SCIENCESen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCOVID-19en_US
dc.subjectmagnetic resonance imagingen_US
dc.subjectsequenceen_US
dc.subjectinterobserver intraclass coefficientsen_US
dc.subjectinterobserver agreementen_US
dc.titleWhich Sequence Should Be Used in the Thorax Magnetic Resonance Imaging of COVID-19: A Comparative Studyen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Which sequence should be used in the thorax magnetic resonance im.pdf
Size:
2.06 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: