Dosimetric Comparison of Volumetric Arc Therapy Methods for Stereotactic Body Radiotherapy in Liver Metastasis

dc.contributor.authorOymak, Ezgi
dc.contributor.authorGueler, Ozan Cem
dc.contributor.authorOenal, Cem
dc.date.accessioned2022-11-03T10:48:47Z
dc.date.available2022-11-03T10:48:47Z
dc.date.issued2022
dc.description.abstractOBJECTIVE Volumetric arc therapy (VMAT) is advantageous for stereotactic body radiotherapy (SBRT) delivery; however, it is still unknown which rotational method is optimal for the treatment of liver metastases. This study aims to compare the dosimetric data of SBRT plans with VMAT techniques and helical tomotherapy (HT) in 18 liver metastasis patients. METHODS Three plans were generated: VMAT(M) was generated with Monaco Treatment Planning System (TPS), VMAT(E) with an Eclipse TPS, and HT plans were generated using a Hi-Art Tomotherapy system. The prescribed dose was 54 Gy delivered in three fractions. The planning target volume (PTV) doses and organs at risk (OAR) doses were compared between three plans. RESULTS All plans met the criteria for PTV coverage. Maximum PTV doses were significantly higher in VMAT(M) plan, and minimum PTV doses were significantly lower in VMAT(E )plan. The dose conformity and ho-mogeneity indices of PTV were better in VMAT(E) plan. Only mean bowel maximum dose was significantly higher in HT plan compared to VMAT(M) plan only. The liver D-mean were significantly higher in PTV larger than 50 cm3. Liver D-mean in PTV > 50 cm(3) was significantly less in VMAT(M )plan compared to HT (p=0.04) and VMAT(E) plans (p=0.04). CONCLUSION All three plans met the criteria for PTV coverage with no significant difference in OARs doses. VMAT(E) plan yielded better homogeneity and conformity in PTV compared to VMAT(M) and HT, and healthy liver tissue was better spared especially in larger tumors (> 50 cm(3)) with VMAT(E) plans.en_US
dc.identifier.issn1300-7467en_US
dc.identifier.scopus2-s2.0-85060032965en_US
dc.identifier.urihttp://onkder.org/pdf/pdf_TOD_1356.pdf
dc.identifier.urihttp://hdl.handle.net/11727/7990
dc.identifier.wos000859281600001en_US
dc.language.isoengen_US
dc.relation.isversionof10.5505/tjo.2022.3702en_US
dc.relation.journalTURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectHelical tomotherapyen_US
dc.subjectliver metastasisen_US
dc.subjectstereotactic body radiotherapyen_US
dc.subjectvolumetric arc therapyen_US
dc.titleDosimetric Comparison of Volumetric Arc Therapy Methods for Stereotactic Body Radiotherapy in Liver Metastasisen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ds155.pdf
Size:
959.66 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: