Is It Essential to Use Fiducial Markers During Cone-Beam CT-Based Radiotherapy for Prostate Cancer Patients?
dc.contributor.author | Yildirim, Berna A. | |
dc.contributor.author | Onal, Cem | |
dc.contributor.author | Dolek, Yemliha | |
dc.contributor.orcID | 0000-0001-6661-4185 | en_US |
dc.contributor.orcID | 0000-0002-2742-9021 | en_US |
dc.contributor.pubmedID | 27730453 | en_US |
dc.contributor.researcherID | V-5717-2017 | en_US |
dc.contributor.researcherID | D-5195-2014 | en_US |
dc.contributor.researcherID | HOC-5611-2023 | en_US |
dc.date.accessioned | 2023-07-20T11:57:44Z | |
dc.date.available | 2023-07-20T11:57:44Z | |
dc.date.issued | 2017 | |
dc.description.abstract | To compare soft-tissue cone-beam computed tomography (CBCT-P) and fiducial marker (CBCT-FM)-based image guided radiotherapy in prostate cancer patients. Sixteen prostate cancer patients were treated with volumetric modulated arc therapy. Manual alignment using CBCT-P and CBCT-FM was performed for each patient. Couch shifts were calculated and compared between methods in the left-right (x), superior-inferior (y), and anterior-posterior (z) directions. CBCT-P and CBCT-FM alignments were compared using 252 scans from the 16 patients. Mean displacement from zero was 2.4 +/- 1.3, 1.7 +/- 1.2, and 1.8 +/- 1.1 mm for CBCT-P and 2.3 +/- 1.3, 1.7 +/- 1.1 and 1.8 +/- 1.1 mm for CBCT-FM in the x, y and z directions, respectively. There was no difference in median displacement between CBCT-P and CBCT-FM; however, there was a significant positive correlation between CBCT-P- and CBCT-FM-based displacements in the x (r = 0.881; p < 0.001), y (r = 0.789; p < 0.001) and z (r = 0.856; p < 0.001) directions by linear regression analysis. Systematic deviations within each group were < 1 mm; however, random and systematic errors were similar in the x and y directions but larger in the z direction. Our study demonstrated that CBCT-FM was not superior to CBCT-P for image-guided radiotherapy in prostate cancer patients. | en_US |
dc.identifier.eissn | 1867-108X | en_US |
dc.identifier.endpage | 9 | en_US |
dc.identifier.issn | 1867-1071 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.scopus | 2-s2.0-84991101957 | en_US |
dc.identifier.startpage | 3 | en_US |
dc.identifier.uri | http://hdl.handle.net/11727/10017 | |
dc.identifier.volume | 35 | en_US |
dc.identifier.wos | 000393591500002 | en_US |
dc.language.iso | eng | en_US |
dc.relation.isversionof | 10.1007/s11604-016-0590-y | en_US |
dc.relation.journal | JAPANESE JOURNAL OF RADIOLOGY | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Prostate cancer | en_US |
dc.subject | Image-guided radiotherapy | en_US |
dc.subject | Cone-beam CT | en_US |
dc.subject | Fiducial marker | en_US |
dc.subject | Setup errors | en_US |
dc.title | Is It Essential to Use Fiducial Markers During Cone-Beam CT-Based Radiotherapy for Prostate Cancer Patients? | en_US |
dc.type | article | en_US |
Files
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: