Comparison of Three-Dimensional Ultrasound and Magnetic Resonance Imaging Diagnosis in Surgically Proven Mullerian Duct Anomaly Cases

dc.contributor.authorErgenoglu, Ahmet Mete
dc.contributor.authorSahin, Cagdas
dc.contributor.authorSimsek, Deniz
dc.contributor.authorAkdemir, Ali
dc.contributor.authorYeniel, Ahmet Ozgur
dc.contributor.authorYerli, Hasan
dc.contributor.authorSendag, Fatih
dc.contributor.orcIDhttps://orcid.org/0000-0003-2463-1758en_US
dc.contributor.pubmedID26699099en_US
dc.contributor.researcherIDAAK-9572-2021en_US
dc.date.accessioned2023-06-22T11:47:36Z
dc.date.available2023-06-22T11:47:36Z
dc.date.issued2016
dc.description.abstractObjective: To determine and compare the diagnostic accuracy of 3-dimensional ultrasound (3D US) and magnetic resonance imagining (MRI) in patients with surgically diagnosed Mullerian duct anomaly (MDA). Study design: Charts of patients with MDA were retrospectively evaluated. Patients who underwent both laparoscopic and hysteroscopic surgery and had 3D US and MRI examinations were included in the study. The diagnoses achieved via 3D US and MRI were compared with the surgical diagnoses to determine the diagnostic accuracy of these imagining techniques. Results: Twenty-nine patients were included in the study. Three-dimensional ultrasound detected 28 out of 29 (96%) patients correctly. Only one patient was diagnosed with a uterine septum instead of uterine arcuatus. Magnetic resonance imaging detected 23 out of 29 patients correctly (79%). The Kappa indexes of the 3D US and MRI were 0.896 and 0.592, respectively. Conclusion: Our results indicate that 3D US has a higher diagnostic accuracy level than MRI in evaluating MDA, especially when used in experienced hands. However, additional, well-designed studies are needed to better compare the diagnostic accuracy of the 3D US and MRI. Crown Copyright (C) 2015 Published by Elsevier Ireland Ltd. All rights reserved.en_US
dc.identifier.endpage26en_US
dc.identifier.issn0301-2115en_US
dc.identifier.scopus2-s2.0-84960192140en_US
dc.identifier.startpage22en_US
dc.identifier.urihttp://hdl.handle.net/11727/9797
dc.identifier.volume197en_US
dc.identifier.wos000371187300005en_US
dc.language.isoengen_US
dc.relation.isversionof10.1016/j.ejogrb.2015.11.010en_US
dc.relation.journalEUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergien_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMullerian duct anomalyen_US
dc.subjectThree-dimensional ultrasonographyen_US
dc.subjectMagnetic resonance imagingen_US
dc.titleComparison of Three-Dimensional Ultrasound and Magnetic Resonance Imaging Diagnosis in Surgically Proven Mullerian Duct Anomaly Casesen_US
dc.typeArticleen_US

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: