Enhanced Stent Imaging System Guided Percutaneous Coronary Intervention Is Linked to Optimize Stent Placement
dc.contributor.author | Avci, Ilhan Ilker | |
dc.contributor.author | Zeren, Gonul | |
dc.contributor.author | Sungur, Mustafa Azmi | |
dc.contributor.author | Akdeniz, Evliya | |
dc.contributor.author | Simsek, Baris | |
dc.contributor.author | Yilmaz, Mehmet Fatih | |
dc.contributor.author | Can, Fatma | |
dc.contributor.author | Gurkan, Ufuk | |
dc.contributor.author | Karagoz, Ali | |
dc.contributor.author | Tanboga, Ibrahim Halil | |
dc.contributor.author | Karabay, Can Yucel | |
dc.contributor.pubmedID | 36178093 | en_US |
dc.date.accessioned | 2022-11-02T10:33:57Z | |
dc.date.available | 2022-11-02T10:33:57Z | |
dc.date.issued | 2022 | |
dc.description.abstract | Stent under-expansion is a predictor of restenosis and stent thrombosis. It remains uncertain whether enhanced stent imaging (ESI) (CLEARstent) guidance can improve stent under-expansion. Our aim was to assess the effect of using ESI on stent under-expansion, after percutaneous coronary intervention (PCI) in a single center, cross-sectional observational study. Participants attending our cardiology clinic with stable angina or acute coronary syndrome, from March to September 2020 were recruited. A total of 164 patients who underwent post-PCI ESI (CLEARstent) were compared with 77 age- and sex-matched control patients. Post-procedural minimal lumen diameter (MLD) was calculated. The patients in the ESI-guided PCI group, had a median age of 61 (54-69 IQR 25-75) years and 76.8% (n = 126) were males. The patients in ESI-guided PCI group had a greater minimal lumen diameter compared with the X-ray guided PCI group (beta eta coefficient:2.88 (95% CI:2.58-2.99) vs beta eta coefficient 2.55 (95% CI 2.34-2.63), P < .001). Our finding supports the use of the ESI system to optimize stent placement as expressed by the MLD. | en_US |
dc.identifier.issn | 0003-3197 | en_US |
dc.identifier.scopus | 2-s2.0-85139174049 | en_US |
dc.identifier.uri | https://assets.researchsquare.com/files/rs-1317662/v1/9775f957-af69-4f3f-ac7d-8081942c511d.pdf?c=1649097185 | |
dc.identifier.uri | http://hdl.handle.net/11727/7957 | |
dc.identifier.wos | 000862491300001 | en_US |
dc.language.iso | eng | en_US |
dc.relation.journal | ANGIOLOGY | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | enhanced stent imaging | en_US |
dc.subject | stent under-expansion | en_US |
dc.subject | minimal lumen diameter | en_US |
dc.title | Enhanced Stent Imaging System Guided Percutaneous Coronary Intervention Is Linked to Optimize Stent Placement | en_US |
dc.type | article | en_US |