Comparison Of The Accuracy Of Three Interproximal Reduction Methods Used In Clear Aligner Treatment

dc.contributor.authorGulec-Ergun, Pelinsu
dc.contributor.authorArman-Ozcirpici, Ayca
dc.contributor.authorAtakan-Kocabalkan, Azize
dc.contributor.authorTuncer, Niluefer Irem
dc.date.accessioned2025-05-15T07:12:22Z
dc.date.issued2024-01-15
dc.description.abstractObjectivesTo comparatively assess 3 interproximal reduction (IPR) methods used in clear aligner treatment with regard to accuracy, and patient perception of discomfort and anxiety.Materials and methodsA total of 42 patients, treated with the Invisalign (R) system, were included in this prospective trial and received one of the following IPR methods: hand-operated abrasive strips (group 1; 14 patients, 150 teeth), motor-driven 3/4 oscillating segmental discs (group 2; 14 patients, 134 teeth), or motor-driven abrasive strips (group 3; 14 patients, 133 teeth). Accuracy was evaluated using the difference between planned and executed IPR. Anxiety and discomfort levels experienced by the patients were evaluated using a questionnaire of 17 questions.ResultsThe accuracy of IPR was high in groups 2 and 3; however, it was low in group 1 with the executed IPR significantly less than the planned amount. On quadrant-level, executed IPR was significantly less in the upper left quadrant in group 1, and significantly more in the upper right quadrant in group 2. The difference between planned IPR and executed IPR was significant for teeth 11, 21, 32, 33, and 43 in group 1, indicating deficiency. The average difference between planned IPR and executed IPR was 0.08 mm for group 1, 0.09 mm for group 2, and 0.1 mm for group 3. Anxiety and discomfort levels did not differ between the methods, but a negative correlation was observed between age and discomfort and anxiety levels.ConclusionsThe overall accuracy of the 2 motor-driven IPR methods was found to be better than the hand-operated system. Maxillary central incisors and mandibular canines were more prone to IPR deficiency when hand-operated abrasive strips were utilized. Patients were similarly comfortable with all 3 methods, and discomfort and anxiety levels decreased with age.Clinical relevanceMotor-driven methods have proven to be more effective when compared to the hand-operated ones by means of precision, speed, and patient comfort. If the clinician favors a hand-operated method, it may be advised to perform slightly more IPR especially on mandibular canines and maxillary central incisors.
dc.identifier.issn1432-6981
dc.identifier.urihttps://hdl.handle.net/11727/13076
dc.identifier.wos001142095400002
dc.language.isoen_US
dc.publisherCLINICAL ORAL INVESTIGATIONS
dc.subjectAbrasive strips
dc.subjectAnxiety
dc.subjectConsistency
dc.subjectOscillating discs
dc.subjectPatient perception
dc.subjectStripping
dc.subjectTOOTH MOVEMENT
dc.subjectINVISALIGN
dc.subjectAPPLIANCES
dc.subjectEFFICACY
dc.subjectMODELS
dc.titleComparison Of The Accuracy Of Three Interproximal Reduction Methods Used In Clear Aligner Treatment
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
784_2024_Article_5499.pdf
Size:
710.38 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: