dc.description.abstractThis research, covers the evaluation of the performance of harware of plasma-based (gas plasma, plasma jet) surgical prototype device which will be used in microsurgery, identification of active device operating conditions with the appropriate engineering models Microsurgery is by taking advantage of the magnifying effect of the special operation microscope, very small structures that can hardly be seen with the naked eye and surgery using very thin instrument. It is necessary to emphasize, the plasma technique using on directly liver cell for the treatment is the novel study. The examples of portable commercial devices in the world have started to increase in the recent past, but they are still few. The project has three main design in general; primarily high voltage power supply, bipolar plasma probe, gas supply control unit made it. High voltage power supply made with transformator and mosfets connecting with push-pull. Bipolar plasma probe, made 2 tungsten rod which mounted on the board mechanism and used teflon wire for connection with high voltage power supply. For the gas supply control unit, used microprocessor controlled and transistor amplifier selenoid valve. Thus, it is aimed to trigger the solenoid valve and adjust the gas flow in the adjustable frequency range. In the first tests made, the formation of radiation of the high voltage circuit was observed. The integration with the tungsten probe system was completed and tried to test the relation between angle and distance and radiation. In addition, the completed parts of the gas supply control unit designed together with the solenoid valve and the microprocessor have been tested. etc.] in its style sheet. As a result, the distance parameter of radiation formation is determined by high voltage circuit tests. Radiation-angle tests were performed and later turned into a prototype with the outer design of the device.en_US
dc.identifier.scopus2-s2.0-85061745477en_US
dc.identifier.urihttp://hdl.handle.net/11727/8802
dc.identifier.wos000467637600006en_US
dc.language.isoturen_US
dc.relation.journal2018 MEDICAL TECHNOLOGIES NATIONAL CONGRESS (TIPTEKNO)en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMicrosurgeryen_US
dc.subjectplasma surgeryen_US
dc.subjectmedical plasmaen_US
dc.titleConfiguration of Hardware for Medical Plasma Based Surgical Device and Featuresen_US
dc.typeConference Objecten_US

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: