Cyclosporine Therapeutic Monitoring With Cmax in Kidney Transplant Recipients: Does it Fit for All Populations?

dc.contributor.authorEl-Agroudy, Amgad E.
dc.contributor.authorGhoneim, Mohamed A.
dc.contributor.authorNassar, Mohamed
dc.contributor.authorIsmail, Amani M.
dc.date.accessioned2025-11-28T06:14:09Z
dc.date.issued2008-12
dc.description.abstractBackground: We sought to assess whether the single cyclosporine concentration taken 2 hours after administration (C2) is a good parameter to predict a drug’s maximal concentration (Cmax) value in Egyptian kidney transplant recipients Materials and Methods: Fifty stable Egyptian kidney transplant recipients with a previously diagnosed schistosomal infection were compared with 50 Egyptian kidney transplant recipients without a schistosomal infection regarding cyclosporine concentrations at time 0 (trough), and then at 1.5, 2, 2.5, 3, and 3.5 hours after a dose of cyclosporine. We used a linear regression analysis to assess any statistically significant differences between the different cyclosporine time concentrations and drug dosages Results: Patients in the schistosomal group had significantly lower C2 levels (511 ± 118 nmol/L) compared with those in the nonschistosomal (control) group (669 ± 213 nmol/L) (P < .05), whereas the C2.5 level was significantly higher (730 ± 215 and 527 ± 129 nmol/L, respectively; P < .05). A significant linear regression relation was determined for only C2.5 in the schistosomal group with both morning cyclosporine dose and cyclosporine dose expressed as mg/kg/d (P = .0123, r = .573018). Conclusions: Egyptian patients have special characteristics with regard to drug absorption and metabolism, mostly owing to schistosomal infection, and they may need the use of C2.5 to monitor cyclosporine. If confirmed by subsequent, larger studies, our findings may have a significant effect on our understanding and management of cyclosporine immunosuppression in clinical renal transplants with persons of different ethnicities.
dc.identifier.citationExperimental and Clinical Transplantation, Cilt, 6, Sayı, 4, 2008 ss. 282-286en
dc.identifier.eissn2146-8427en
dc.identifier.issn1304-0855
dc.identifier.issue4en
dc.identifier.urihttps://hdl.handle.net/11727/13992
dc.identifier.volume6en
dc.language.isoen_US
dc.publisherBaşkent Üniversitesi
dc.sourceExperimental and Clinical Transplantationen
dc.subjectCyclosporine
dc.subjectCmax monitoring
dc.titleCyclosporine Therapeutic Monitoring With Cmax in Kidney Transplant Recipients: Does it Fit for All Populations?
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
282.pdf
Size:
124.16 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: