PubMed İndeksli Açık & Kapalı Erişimli Yayınlar

Permanent URI for this communityhttps://hdl.handle.net/11727/10756

Browse

Search Results

Now showing 1 - 2 of 2
  • Item
    Root Canal Length Measurement of Molar Teeth Using Cone- Beam Computed Tomography (CBCT): Comparison of Two-Dimensional Versus Three-Dimensional Methods
    (2021) Sisli, Selen Nihal; Gulen, Orhan; 34250476
    Purpose This study aimed to evaluate the validity of 2-dimensional (2D) and 3-dimensional (3D) cone-beam computed tomographic (CBCT) root canal length measurements of molar teeth compared with actual root canal lengths and the influence of canal curvature on the accuracy of CBCT measurements. Materials and Methods Seventy root canals of 24 molar teeth were scanned using CBCT, and the root canals were categorized as; 'straight/curved:'highly curved" and 'multiple curved!The 2D measurements were performed within a suitable slice between the major foramen and the corresponding cusp. The 3D measurements were performed within the slices in regular intervals of axial planes in between the same reference points. The reproducibility and reliability of the methods were analyzed by intraclass correlation coefficient. Differences between the actual and CBCT root canal lengths were evaluated by chi-square and McNemar tests if the measurements were within acceptable limits of +/- 0.5 mm. Results Both methods were found to be reproducible and presented excellent reliability. However, the 3D method was significantly more accurate, with an 85.7% frequency of measurements within accepta ble limits (p<0.05). In 'multiple curved' root canals, the 3D method presented more reliable measurements than the 2D method. For 'straight/curved' root canals, the 2D method gave results significantly closer to the actual root canal length in comparison with 'highly curved' root canals (p<0.05). Conclusion The 3D measurements are more accurate than 2D measurements. If an already existing CBCT is present, it could be an alternative method for predetermination of root canal lengths in molar teeth.
  • Item
    Evaluation of Mandibular Third Molar Region in a Turkish Population Using Cone-Beam Computed Tomography
    (2020) Orhan, Buyuk Kaan; Yilmaz, Dilek; Ozemre, Mehmet Ozgur; Kamburoglu, Kivanc; Gulen, Orhan; Gullsahi, Ayse; 0000-0002-4134-5756; 33135608; AAG-1491-2021
    Objectives: To evaluate impacted mandibular third molar tooth region and obtain linear measurements using CBCT images and to assess the relationship between the impacted third molar and the mandibular canal. Methods: CBCT scans of 351 patients (208 females, 143 males) were assessed. Age, gender, and impaction site were recorded for each patient. The relationship of third molars with the vertical axis of second molars, 2nd molar resorption and the relationship between third molar apices and the mandibular canal were assessed. In addition, the distance between ramus and second molar, mesiodistal width of the third molar, the angle between third molar and second molar, and width of the third molar capsule were measured. Binary Logistic Regression, Chi-Square Test, and General Linear Model were used for statistical analysis. Results: The highest percentage of impaction was found for mesioangular followed by transversal and vertical. The transversal impacted third molars revealed a significant association with adjacent second molar root resorption (p<0.001). There was a statistical significance between the second molar resorption and distance between ramus and second molar (p<0.001). The mesioangular impacted third molars revealed significant relation with the mandibular canal (p<0.05). The most frequent variation found was the dental canal followed by the retromolar canal. In general, higher measurement values were obtained for men when compared to women (p<0.05). Conclusion: CBCT assessment of the third molar region provided useful information regarding impacted mandibular third molar surgery operations.