TR-Dizin İndeksli Açık & Kapalı Erişimli Yayınlar

Permanent URI for this communityhttps://hdl.handle.net/11727/10755

Browse

Search Results

Now showing 1 - 3 of 3
  • Item
    A newborn case diagnosed as isolated TBX1 deletion with 22q11 deletion syndrome
    (2020) Turan, Ozden; Celik, Zerrin Yilmaz; Ince, Deniz Anuk; Terzi, Yunus Kasim; Ecevit, Ayse; 0000-0002-2232-8117; 0000-0002-7707-1881; 0000-0002-4369-2110; AAJ-4616-2021; AAJ-2333-2021; I-6746-2016
  • Thumbnail Image
    Item
    Inferior Vena Cava Oxygen Saturation during the First Three Postnatal Days in Preterm Newborns with and without Patent Ductus Arteriosus
    (2014) Yapakci, Ece; Ecevit, Ayse; Ince, Deniz Anuk; Gokdemir, Mahmut; Tekindal, M. Agah; Gulcan, Hande; Tarcan, Aylin; 25337418
    Background: Inferior vena cava (IVC) oxygen saturation as an indicator of mixed venous oxygenation may be valuable for understanding postnatal adaptations in newborn infants. It is unknown how this parameter progresses in critically ill premature infants. Aims: To investigate IVC oxygen saturation during the first three days of life in preterm infants with and without patent ductus arteriosus (PDA). Study Design: Case-control study. Methods: Twenty-seven preterm infants were admitted to the Neonatal Intensive Care. Preterm infants with umbilical venous catheterization were included in the study. Six umbilical venous blood gas values were obtained from each infant during the first 72 hours of life. Preterm infants in the study were divided into two groups. Haemodynamically significant PDA was diagnosed by echocardiography in 11 (41%) infants before the 72nd hour of life in the study group and ibuprofen treatment was started, whereas 16 (59%) infants who didn't have haemodynamically significant PDA were included in the control group. Results: In the entire group, the highest value of mean IVC oxygen saturation was 79.9% at the first measurement and the lowest was 64.8% at the 72nd hour. Inferior vena cava oxygen saturations were significantly different between the study and control groups. Posthoc analysis revealed that the first and 36th hour measurements made the difference (p=0.01). Conclusion: Inferior vena cava oxygen saturation was found to be significantly different between preterm infants with and without PDA. Further studies are needed to understand the effect of foetal shunts on venous oxygenation during postnatal adaptation in newborn infants.
  • Thumbnail Image
    Item
    Assessment of Endotracheal Tube Position After Oral Intubation in Neonates
    (2018) Ince, Deniz Anuk; Gul, Ali; Takci, Sahin; Unuvar, Seyma
    Aim: Endotracheal intubation is a common procedure in the delivery room and neonatal intensive care unit. We aimed to determine the accuracy of this method of endotracheal tube (ETT) placement in our neonatal cohort. Materials and Methods: Data on infants requiring oral intubation were reviewed retrospectively. The initial ETT depth of insertion had been calculated using the Tochen 7-8-9 rule. The initial depth was compared to the mid-tracheal region. The differences between the initial and ideal depth was calculated and divided by the mid-tracheal distance. Infants were grouped according to their weights as <= 1000 g,1001 to 2000 g, 2001 to 3000 g and >= 3001g. Results: We evaluated ETT placement in 160 neonates. The mean gestational age was 32.2 +/- 4.4 weeks (23 to 41 weeks) and the mean weight was 1989 +/- 829 g (560 to 3800 g). The mean range of the difference between the initial depth and ideal depth divided by mid-tracheal distance was 0.39 +/- 0.04, 0.35 +/- 0.04, 0.46 +/- 0.05, and 0.23 +/- 0.04 in infants weighing <= 1000 g, 1001 to 2000 g, 2001 to 3000 g and >= 3001 g respectively (p=0.025). The differences between the 2001-3000 g group and the 1001-2000, also the 2001-3000 g group and the >= 3001 g group were statistically significant (p<0.05). Conclusion: The 7-8-9 rule should be used to assess ETT length in neonates, especially in those weighing more than 3 kg. As this rule has low accuracy for extremely low birth weight neonates, its reliability may not be high for neonates weighing less than 3 kg in weight.