Scopus İndeksli Açık & Kapalı Erişimli Yayınlar

Permanent URI for this communityhttps://hdl.handle.net/11727/10752

Browse

Search Results

Now showing 1 - 2 of 2
  • Item
    Results of Balloon and Surgical Valvuloplasty in Congenital Aortic Valve Stenosis: A 19-Year, Single-Center, Retrospective Study
    (2021) Yakut, Kahraman; Varan, Birgul; Tokel, Niyazi Kursad; Erdogan, Ilkay; Ozkan, Murat; 0000-0002-6719-8563; 0000-0001-6887-3033; 34104509; ABB-1767-2021; ABB-2220-2021
    Background: This study aims to compare the success, complications, and long-term outcomes of aortic balloon valvuloplasty and surgical aortic valvuloplasty in pediatric patients with congenital aortic valve stenosis. Methods: Between March 2000 and October 2019, a total of 267 procedures, including 238 balloon valvuloplasties and 29 surgical valvuloplasties, in 198 children (135 males, 63 females; mean age: 57.4 +/- 62.6 months; range, 0.03 to 219 months) were retrospectively analyzed. The hospital records, echocardiographic images, catheterization data, angiography images, and operative data were reviewed. Results: Aortic regurgitation was mild in 73 patients before balloon valvuloplasty, and none of the patients had moderate-to-severe aortic regurgitation. Compared to surgical valvuloplasty, the rate of increase in the aortic regurgitation after balloon valvuloplasty was significantly higher (p=0.012). The patients who underwent balloon valvuloplasty did not need reintervention for a mean period of 46 +/- 45.6 months, whereas this period was significantly longer in those who underwent surgical valvuloplasty (mean 80.5 +/- 53.9 months) (p=0.018). The overall failure rate was 8%. Moderate-to-severe aortic regurgitation was the most important complication developing due to balloon valvuloplasty in the early period (13%). All surgical valvuloplasties were successful. The mean length of hospitalization after balloon valvuloplasty was significantly shorter than surgical valvuloplasty (p=0.026). During follow-up, a total of 168 patients continued their follow-up, and a reinterventional or surgical intervention was not needed in 78 patients (47%). Conclusion: Aortic balloon valvuloplasty can be repeated safely and helps to eliminate aortic valve stenosis without needing sternotomy. Surgical valvuloplasty can be successfully performed in patients in whom the expected benefit from aortic balloon valvuloplasty is not achieved.
  • Item
    Direct aortic transcatheter aortic valve implantation
    (2021) Karacaglar, Emir; Akgun, Arzu Neslihan; Aydinalp, Alp; Beyazpinar, Deniz Sarp; Sezgin, Atila; Muderrisoglu, Haldun; 34623302
    Transcatheter aortic valve implantation (TAVI) is a safe and effective alternative to surgical valve replacement in intermediate and even in low-risk patient cohorts. Direct aortic (DAo) route may be used in patients with severe peripheral vascular disease. Here, we present an 88-year old patient hospitalized with cardiogenic shock. Echocardiography revealed severe aortic valve stenosis with aortic valve area 0.5 cm(2), mean gradient of 55 mmHg, and peak gradient 92 mmHg. TAVI was considered by the Institutional Heart Team. Multislice computed tomography (MSCT) revealed severe peripheral vascular disease, decreased calibration of abdominal aorta, and multiple large vulnerable atherosclerotic plaques. The patient was scheduled for a DAo TAVI. A 26-mm Medtronic CoreValve Evolut R valve was implanted after predilatation with median sternotomy. The patient was discharged after 96 hours. Although transfemoral (TF) access is used as the default approach for TAVI, it was contraindicated in our patient owing to severe peripheral vascular disease and decreased calibration of the abdominal aorta at its narrowest point (4.5 mm) with multiple large vulnerable atherosclerotic plaques. Careful preprocedural MSCT evaluation is essential and directly affects the success of the procedure. MSCT is also mandatory to confirm the best cannulation zone that must be met for a successful DAo TAVI.