PubMed İndeksli Yayınlar Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/11727/4810
Browse
6 results
Search Results
Item Accuracy of high-resolution ultrasound (US) for gingival soft tissue thickness mesurement in edentulous patients prior to implant placement(2021) Sonmez, Gul; Kamburoglu, Kivanc; Gulsahi, Ayse; 33201732Objectives: To evaluate and compare the accuracy of high-resolution ultrasound (US) with two different cone beam CT (CBCT) units and clinical assessment for measuring gingival soft tissue thickness in edentulous patients prior to implant placement. Methods and materials: The study consisted of 40 maxillary implant sites of 40 healthy patients (20 females, 20 males; mean age, 47.88 years). We prospectively evaluated labial/buccal gingival thickness in 40 implant regions (16 anterior and 24 posterior) by using limited field of view (FOV) CBCT images and US images in comparison to gold standard transgingival probing measurements. One-way analysis of variance (ANOVA) was used to compare mean measurements obtained from CBCT (Morita and Planmeca), US, and transgingival probing. Interclass correlation coefficient (ICC) estimates were calculated based on means with two-way mixed and absolute-agreement model. Bland Altman plot was used to describe agreement between clinical vs US and CBCT measurements by constructing limits of agreement. Statistical significance was set at p < 0.05. Results: There was no significant difference between methods used according to mean gingival thickness measurements obtained from the top (p = 0.519) and bottom (p = 0.346) of the alveolar process. US and CBCT measurements highly correlated with clinical measurements for both top and bottom alveolar process gingival thickness (p < 0.001). Distribution of differences between clinical measurements and both CBCT measurements showed statistically significant differences according to 0 (p < 0.05). Distribution of differences between clinical measurements and US measurements did not show statistically significant difference (p > 0.05). Conclusion: High-resolution US provided accurate information for the measurement of gingival soft tissue thickness in edentulous patients prior to implant placement.Item Effect of cone beam computed tomography voxel size and dental specialty status on the agreement of observers in the detection and measurement of periapical lesions(2021) Kamburoglu, Kivanc; Koc, Emre; Sonmez, Gul; Elbahary, Shlomo; Rosen, Eyal; Tsesis, Igor; 34120879Objective. To compare observer agreement between endodontists and oral and maxillofacial radiologists (OMRs) in the detection and measurement of periapical lesions as depicted in cone beam computed tomography (CBCT) with 2 voxel sizes. Study Design. In total, 256 CBCT images of maxillary molars were evaluated by 2 endodontists and 2 OMRs. Images were obtained at voxel sizes of 0.2 and 0.4 mm. Observers evaluated 64 endodontically and 64 nonendodontically treated teeth for the presence of periapical lesions using a 5-point confidence scale. Weighted k values were calculated to determine intra- and interobserver agreement. Intraclass correlation coefficients (ICCs) were calculated to assess intra- and interobserver agreement in width and height measurements of the lesions. Results. Intraobserver agreement ranged from fair to almost perfect, with k values higher for the OMRs than for the endodontists. Interobserver agreement between endodontists ranged from fair to moderate at the 0.2mm voxel size and was slight at 0.4 mm. Agreement between OMRs was almost perfect at 0.2 mm and ranged from substantial to almost perfect at 0.4 mm. ICC was excellent for all observers in all conditions. Conclusions. Intra- and interobserver reliability was affected by voxel size and specialty. Correlation for measurements exhibited no variation.Item Evaluation of Mandibular Third Molar Region in a Turkish Population Using Cone-Beam Computed Tomography(2020) Orhan, Buyuk Kaan; Yilmaz, Dilek; Ozemre, Mehmet Ozgur; Kamburoglu, Kivanc; Gulen, Orhan; Gullsahi, Ayse; 0000-0002-4134-5756; 33135608; AAG-1491-2021Objectives: To evaluate impacted mandibular third molar tooth region and obtain linear measurements using CBCT images and to assess the relationship between the impacted third molar and the mandibular canal. Methods: CBCT scans of 351 patients (208 females, 143 males) were assessed. Age, gender, and impaction site were recorded for each patient. The relationship of third molars with the vertical axis of second molars, 2nd molar resorption and the relationship between third molar apices and the mandibular canal were assessed. In addition, the distance between ramus and second molar, mesiodistal width of the third molar, the angle between third molar and second molar, and width of the third molar capsule were measured. Binary Logistic Regression, Chi-Square Test, and General Linear Model were used for statistical analysis. Results: The highest percentage of impaction was found for mesioangular followed by transversal and vertical. The transversal impacted third molars revealed a significant association with adjacent second molar root resorption (p<0.001). There was a statistical significance between the second molar resorption and distance between ramus and second molar (p<0.001). The mesioangular impacted third molars revealed significant relation with the mandibular canal (p<0.05). The most frequent variation found was the dental canal followed by the retromolar canal. In general, higher measurement values were obtained for men when compared to women (p<0.05). Conclusion: CBCT assessment of the third molar region provided useful information regarding impacted mandibular third molar surgery operations.Item Comparison of mandibular index values determined from standard panoramic versus cone beam computed tomography reconstructed images(2019) Secgin, Cansu Koseoglu; Gulsahi, Ayse; Yavuz, Yasemin; Kamburoglu, Kivanc; 30497908Objective. The aim of this study was to compare mandibular index values, including the mandibular cortical index (MCI), mental index (MI), and panoramic mandibular index (PMI), determined on the basis of cone beam computed tomography (CBCT) and panoramic reconstructed (PR) images. Study Design. PR and CBCT images of 182 patients were retrospectively analyzed. Cross-sectional (CS) and PR images were obtained from CBCT data. The MCI, MI, and PMI were assessed on CS, PR, and panoramic images and evaluated for intra- and interobserver agreements by kappa-value or intraclass correlation coefficient (ICC) analysis. Agreement among measurement methods was assessed by using the Bland-Altman method, with CS images as the gold standard for linear measurements. Results. Measurements from PR and CS images agreed with those from panoramic images in 66.7% and 53.8% of C3 classifications of MCI (porous cortices forming many endosteal residues), respectively. Panoramic and CBCT images exhibited good agreement in MI findings (ICC 0.91) and moderate (PR and panoramic images: ICC 0.79) to good (CS and panoramic images: ICC 0.87) agreement in PMI findings. Conclusions. Because of the overlapping of buccal and lingual cortices, panoramic images are especially inadequate for determining the C3 category of MCI. However, CS images obtained from available CBCT data provide better visibility compared with panoramic images and, therefore, can be used for evaluating mandibular indices.Item Evaluation of maxillary trabecular microstructure as an indicator of implant stability by using 2 cone beam computed tomography systems and micro-computed tomography(2019) Kulah, Kivanc; Gulsahi, Ayse; Kamburoglu, Kivanc; Geneci, Ferhat; Ocak, Mert; Celik, H. Hamdi; Ozen, Tuncer; 30595501Objective. The aim of this study was to assess the trabecular microarchitecture of the maxilla by using cone beam computed tomography (CBCT) and micro-computed tomography (micro-CT) ex vivo. Study Design. Seventeen maxillary cadaver specimens were scanned by using micro-CT and CBCT devices. Samples were scanned with 2 CBCT devices at different voxel sizes (0.08, 0.125, and 0.160 mm for 3-D Accuitomo 170; 0.75 and 0.200 mm for Planmeca Promax 3-D Max). Morphometric parameters, such as bone volume/total volume (BV/TV) ratio, trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), trabecular number (Tb.N), and degree of anisotropy (DA) were assessed by using CTAnalyzer software. Bland-Altman limits of agreement and intraclass correlation coefficient (ICC) were performed to evaluate agreement between CBCT and micro-CT in consideration of measured morphometric parameters. Statistical significance was set at P < .05. Results. The BV/TV, Tb.Th, Tb.Sp, and DA values were higher for CBCT images compared with micro-CT images, whereas the Tb. N value was lower with CBCT images than with micro-CT images. The BV/TV and DA parameters showed the highest agreement between CBCT and micro-CT devices (ICC = 0.421 for BV/TV and ICC = 0.439 for DA; P < .01). Conclusions. The BV/TV and DA parameters measured on CBCT obtained at the smallest voxel size were found to be useful for the assessment of maxillary trabecular microstructure.Item Versatility of high resolution ultrasonography in the assessment of granulomas and radicular cysts: a comparative in vivo study(2019) Sonmez, Gul; Kamburoglu, Kivanc; Yilmaz, Funda; Koc, Cemre; Baris, Emre; Tuzuner, Aysegul; 31188679Objectives: To evaluate and compare the diagnostic potential of high resolution ultrasound with periapical radiographs (PR) and CBCT in assessing granulomas and radicular cysts. Methods: This study included a total of 33 teeth from 33 patients with periapical lesions. Subjects were distributed among three groups. A consisted of teeth that were extracted. B consisted of teeth treated with root-canal treatment followed by apical surgery. C consisted of teeth treated with root-canal treatment only. Pre-treatment PR, ultrasound and CBCT images were obtained for Groups A, B and C and 6 month post-treatment PR and ultrasound images were obtained for Groups B and C. In addition, histopathological analysis was performed on lesions in Groups A and B. Lesions were classified as either cystic lesions or granulomas. Width, height, depth, surface area and volume of lesions were measured using the built-in softwares of the appropriate imaging modalities. Measurements were compared by Wilcoxon and paired sample t tests. Ultrasound and histopathological findings were compared with lc and Mc Nemar. Statistical significance was set at p < 0.05. Results: kappa coefficient (0.667; p = 0.002) suggested good agreement between ultrasound and histopathology. No statistically significant differences were found among periapical radiography, CBCT and ultrasound in the pre-treatment measurements of lesion width ( p = 0.308) or between CBCT and periapical radiography in the pre-treatment measurements of lesion height ( p = 0.863). In all cases, mean measurement values for all variables were lower for ultrasound than for CBCT. Conclusion: Ultrasound provided useful information for the diagnosis and assessment of granulomas and radicular cysts.