PubMed İndeksli Yayınlar Koleksiyonu

Permanent URI for this collectionhttps://hdl.handle.net/11727/4810

Browse

Search Results

Now showing 1 - 2 of 2
  • Item
    Effect of cone beam computed tomography voxel size and dental specialty status on the agreement of observers in the detection and measurement of periapical lesions
    (2021) Kamburoglu, Kivanc; Koc, Emre; Sonmez, Gul; Elbahary, Shlomo; Rosen, Eyal; Tsesis, Igor; 34120879
    Objective. To compare observer agreement between endodontists and oral and maxillofacial radiologists (OMRs) in the detection and measurement of periapical lesions as depicted in cone beam computed tomography (CBCT) with 2 voxel sizes. Study Design. In total, 256 CBCT images of maxillary molars were evaluated by 2 endodontists and 2 OMRs. Images were obtained at voxel sizes of 0.2 and 0.4 mm. Observers evaluated 64 endodontically and 64 nonendodontically treated teeth for the presence of periapical lesions using a 5-point confidence scale. Weighted k values were calculated to determine intra- and interobserver agreement. Intraclass correlation coefficients (ICCs) were calculated to assess intra- and interobserver agreement in width and height measurements of the lesions. Results. Intraobserver agreement ranged from fair to almost perfect, with k values higher for the OMRs than for the endodontists. Interobserver agreement between endodontists ranged from fair to moderate at the 0.2mm voxel size and was slight at 0.4 mm. Agreement between OMRs was almost perfect at 0.2 mm and ranged from substantial to almost perfect at 0.4 mm. ICC was excellent for all observers in all conditions. Conclusions. Intra- and interobserver reliability was affected by voxel size and specialty. Correlation for measurements exhibited no variation.
  • Item
    Evaluation of maxillary trabecular microstructure as an indicator of implant stability by using 2 cone beam computed tomography systems and micro-computed tomography
    (2019) Kulah, Kivanc; Gulsahi, Ayse; Kamburoglu, Kivanc; Geneci, Ferhat; Ocak, Mert; Celik, H. Hamdi; Ozen, Tuncer; 30595501
    Objective. The aim of this study was to assess the trabecular microarchitecture of the maxilla by using cone beam computed tomography (CBCT) and micro-computed tomography (micro-CT) ex vivo. Study Design. Seventeen maxillary cadaver specimens were scanned by using micro-CT and CBCT devices. Samples were scanned with 2 CBCT devices at different voxel sizes (0.08, 0.125, and 0.160 mm for 3-D Accuitomo 170; 0.75 and 0.200 mm for Planmeca Promax 3-D Max). Morphometric parameters, such as bone volume/total volume (BV/TV) ratio, trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), trabecular number (Tb.N), and degree of anisotropy (DA) were assessed by using CTAnalyzer software. Bland-Altman limits of agreement and intraclass correlation coefficient (ICC) were performed to evaluate agreement between CBCT and micro-CT in consideration of measured morphometric parameters. Statistical significance was set at P < .05. Results. The BV/TV, Tb.Th, Tb.Sp, and DA values were higher for CBCT images compared with micro-CT images, whereas the Tb. N value was lower with CBCT images than with micro-CT images. The BV/TV and DA parameters showed the highest agreement between CBCT and micro-CT devices (ICC = 0.421 for BV/TV and ICC = 0.439 for DA; P < .01). Conclusions. The BV/TV and DA parameters measured on CBCT obtained at the smallest voxel size were found to be useful for the assessment of maxillary trabecular microstructure.