Wos İndeksli Yayınlar Koleksiyonu
Permanent URI for this collectionhttps://hdl.handle.net/11727/4807
Browse
11 results
Search Results
Item Comparison of refractive outcomes using Scheimpflug Holladay equivalent keratometry or IOLMaster 700 keratometry for IOL power calculation(2021) Aksoy, Mustafa; Asena, Leyla; Gungor, Sirel Gur; Kucukoduk, Ali; Akman, Ahmet; 0000-0001-8024-4758; 33733281Purpose This study aims to compare postoperative refractive error results using Pentacam (Oculus Optikgerate GmbH) Holladay equivalent keratometry readings (EKR) or IOLMaster 700 (Carl Zeiss Meditec AG) keratometry (K) values in IOL power calculation. Material and methods This retrospective study included 54 eyes of 31 patients who underwent cataract surgery. Preoperative biometric measurements of all patients were obtained using IOLMaster 700 followed by Pentacam measurements. IOLMaster 700 K measurements on horizontal (K1) and vertical (K2) axes and EKR measurements on 2 mm (EKR2mm), 3 mm (EKR3mm) and 4.5 mm (EKR4.5 mm) corneal zones were recorded. EKR4.5 mm value and IOLMaster 700 K values were used in Holladay-II, SRK/T, Haigis, and Hoffer-Q formulas to calculate predictive refractive error (PRE). Absolute refractive error (ARE) was calculated as the absolute difference between actual postoperative refractive error (APRE) and PRE values. Results Mean age was 72.2 +/- 8.3 (51-87) years and mean IOL power was 21.5 +/- 2.9 D (18-23 D). There was no significant difference between PRE values when IOLMaster 700 K measurements and EKR4.5 mm K measurements were used in Holladay-II, SRK/T, Haigis, and Hoffer-Q formulas (p = 0.571, p = 0.833, p = 0.165, p = 0.347, respectively). There was no significant difference between APRE and ARE values (p = 0.124). According to mean ARE results, the closest estimate was achieved when the IOLMaster 700 K values were used in the Holladay-II formula (p = 0.271). Conclusion IOLMaster 700 K measurement and Pentacam EKR4.5 mm measurements can be used interchangeably. IOLMaster 700 K values yielded the most predictive measurement of the refractive result using the Holladay-II formula.Item Effects of topical Coenzyme Q10, Xanthan Gum and Sodium Hyaluronate on corneal epithelial wound healing(2021) Asena, Leyla; Gokgoz, Gulsah; Helvacioglu, Fatma; Ozgun, Gonca; Deniz, Emine Ebru; Altinors, Dilek Dursun; 0000-0002-6848-203X; 0000-0002-4837-7937; 0000-0002-6026-0045; 34134604; E-5914-2016; AAY-7932-2021; AAH-8887-2021Background: The aim was to compare the effects of three different eye drops on corneal epithelial wound healing in an experimental model. Methods: Twenty-four eyes of 24 female BALB/c mice were included. A 2 mm central corneal epithelial defect was created. Topical Coenzyme Q10 + Vitamin E D-alpha-TPGS 4 x 1 was applied to Group A (n = 6), topical Sodium hyaluronate + Xanthan Gum + 0.3% Nethylmicine 4 x 1 to Group B (n = 6) and topical Sodium hyaluronate 4 x 1 to Group C (n = 6). Group D (n = 6) was the control group without treatment. Clinical scoring according to corneal fluorescein staining and histopathological evaluations was performed. Results: Clinical scores according to corneal fluorescein staining were similar in all groups on days 1 (p = 0.05), 2 (p = 0.15) and 3 (p = 0.62). Electron microscopy revealed disruption of intercellular junctions between corneal epithelial cells and intracellular vacuole formation in all groups except Group A. Corneal epithelial thickness and superficial epithelial microvillus arrangement were close to normal in Group A. Conclusion: Although there was no difference in clinical scores between groups, electron microscopy revealed a better organised epithelium with normal configuration of microvilli and less vacuolisation in Group AItem Changes in ocular biometric parameters after renal transplantation(2020) Aksoy, Mustafa; Asena, Leyla; Gungor, Sirel Gur; Soy, Ebru H. Ayvazoglu; Akman, Ahmet; Haberal, Mehmet; 0000-0002-3462-7632; 0000-0002-0993-9917; 0000-0001-6178-8362; 0000-0002-6848-203X; 0000-0003-1513-7686; 32415655; AAJ-8097-2021; AAC-5566-2019; E-5914-2016; AAD-5967-2021Purpose This study aimed to investigate the changes in postoperative ocular biometric parameters in end-stage renal disease patients who underwent renal transplantation. Material and methods This retrospective study included a total of 33 eyes of 33 patients. The ocular biometric measurements which were evaluated were axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), corneal keratometry (K1 and K2), degree of astigmatism, lens thickness (LT), and intraocular pressure (IOP). Refractive prediction error (RE) was calculated before and after renal transplantation using the same diopter (D) for intraocular lens (IOL) power calculation and evaluated for potential cataract surgery. Results The study included 15 male (45%) and 18 female (55%) patients. Mean patient age was 31.55 +/- 8.24 (range: 18-49 years). In the comparison of preoperative and 1-month postoperative measurements, there was a statistically significant difference in AL, LT, ACD, and CCT (p < 0.001). There was no statistically significant difference between K1, K2, and astigmatism measurements (p = 0.72; p = 0.35; p = 0.62, respectively). There was no statistically significant difference in RE (p = 0.61-Holladay 2). Conclusion While renal transplantation surgery does not lead to significant changes in astigmatism, predicted refractive error, corneal keratometry, or intraocular pressure, it causes significant decrease in axial length, lens thickness, and central corneal thickness and significant increase in anterior chamber depth. However, these changes do not result in significant changes in IOL power calculation in planned cataract surgery.Item Galectin-3, IL-1A, IL-6, and EGF Levels in Corneal Epithelium of Patients With Recurrent Corneal Erosion Syndrome(2020) Candar, Tuba; Asena, Leyla; Alkayid, Husamadden; Altinors, Dilek D.; 0000-0001-5223-0279; 0000-0002-6848-203X; 32732704; E-5914-2016; AAK-8077-2021Purpose: To determine the galectin-3 (Gal3), interleukin-1 (IL-1), interleukin-6 (IL-6), and epidermal growth factor (EGF) levels in corneal epithelium of patients with recurrent corneal erosion (RCE) syndrome and compare them with healthy controls. Methods: In this prospective interventional case control study, 32 eyes of 32 patients with RCE syndrome who had corneal epithelial erosions and 28 eyes of 28 healthy participants scheduled for photorefractive keratectomy (control group) were included. Exclusion criteria included corneal dystrophies, ectasia, dry eye, previous ocular surgery or topical medications, and systemic diseases. Epithelial samples were obtained during epithelial debridement in the study group and mechanical epithelial keratectomy in the control group. Galectin-3 levels were studied by the chemiluminescent microparticle immunoassay method. IL-1, IL-6, and EGF levels were determined using corresponding ELISA kits. Results: The median Gal3 levels were 132.25 ng/mL in the study group and 106.50 ng/mL in the control group. The median IL-1 and IL-6 levels were 6.24 pg/mL and 10.16 pg/mL, respectively, in the study group which were higher than that in the control group. The median EGF level in the study group was lower than that the control group with 1.30 pg/mL versus 2.67 pg/mL. In the control group, there was a significant positive correlation between EGF and IL-6 (r = 0.554;P= 0.040). A similar correlation was not observed in patients with RCE (r = -0.071;P= 0.794). Conclusions: The lack of increased EGF expression and the imbalance between growth factors, adhesion molecules, and interleukins may be the reason for the impaired wound healing response in RCE syndrome.Item VISUAL REHABILITATION AFTER PENETRATING KERATOPLASTY(2020) Asena, Leyla; Altinors, Dilek Dursun; Oto, SibelItem LIMBAL STEM CELL TRANSPLANTATION FOR RESTORATION OF THE OCULAR SURFACE HEALTH IN BILATERAL LIMBAL STEM CELL DEFICIENCY(2020) Altinors, Dilek Dursun; Asena, Leyla; Oto, SibelItem SIMPLE LIMBAL EPITHELIAL TRANSPLANTATION (SLET) IN A PATIENT WITH LIMBAL STEM CELL DEFICIENCY(2020) Altinors, Dilek Dursun; Asena, Leyla; Oto, SibelItem CHANGES IN OCULAR BIOMETRIC PARAMETERS AFTER RENAL TRANSPLANTATION(2020) Aksoy, Mustafa; Asena, Leyla; Gungor, Sirel Gur; Soy, Ebru H. Ayvazoglu; Haberal, Mehmet A.Item THE EFFECT OF CORNEAL TRANSPLANTATION ON VISUAL FUNCTION AND VISION-RELATED QUALITY OF LIFE(2020) Asena, Leyla; Altinors, Dilek Dursun; Oto, SibelItem Evaluation of quality of life after implantation of a new trifocal intraocular lens(2019) Akman, Ahmet; Asena, Leyla; Ozturk, Caner; Gungor, Sirel Gur; 0000-0001-6178-8362; 0000-0002-6848-203X; 30612749; E-5914-2016; AAD-5967-2021Purpose: To evaluate the vision-related quality of life (QOL) after implantation of a new trifocal intraocular lens (IOL), by using the National Eye Institute Visual Function Questionnaire-14 (VF-14 QOL questionnaire). Setting: Baskent University Faculty of Medicine, Department of Ophthalmology, Ankara, Turkey. Design: Prospective noncomparative case series. Methods: Consecutive patients who had a new trifocal IOL (Pan-Optix) bilaterally implanted were included in the study. The vision-related QOL was assessed 3 months after the surgery in the second eye. The VF-14 QOL questionnaire was used, with a grading scale of 0, no difficulty; 1, a little difficulty; 2, moderate difficulty; 3, quite difficult; 4, impossible to perform. A subgroup of 14 patients, with an interval of at least 3 months between the surgery in the first eye and the surgery in the fellow eye, were also interviewed 3 months after the monocular IOL implantation. In this subgroup, the QOL with monocular and binocular implantation was compared. Results: The study comprised 48 patients. Reading small print, driving at night, and doing fine handwork were the most difficult tasks to perform, with the mean values of the VF-14 QOL questionnaire being 0.94 +/- 0.81 (SD), 0.89 +/- 0.68, and 0.64 +/- 0.67, respectively. Binocular implantation was associated with improvement in vision-related QOL when compared with monocular implantation, with significant differences in doing fine handwork such as sewing (P = .02) and using a computer (P = .03). Conclusions: With mean values of 1.00 or lower for each question, the results of the VF-14 QOL questionnaire indicated that patients who have the new trifocal IOL bilaterally implanted have an overall high satisfaction rate and a high vision-related QOL. (C) 2018 ASCRS and ESCRS