Repository logo
Communities & Collections
All of DSpace
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Masri, Marwan A"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • No Thumbnail Available
    Item
    Bioavailability versus Bioequivalence: The Cyclosporine Model
    (Başkent Üniversitesi, 2003-12) Masri, Marwan A
    The quest for a fixed-dose immunosuppressive drug continues. Experience with cyclosporine, tacrolimus and mycophenolate mofetil has taught us that there is no correlation between dose and clinical events. These data indicate that the concentration of the drug at the site of action (bioavailability) of each of these agents differs from one patient to the next. In addition, the bioequivalence (concentration of intact drug at the site of action resulting in a measurable response [effect]) may differ among individuals. Technically, it is very difficult to measure the drug concentration at a particular site, especially in organs or tissues that are not directly accessible. Therapeutic drug-blood-level monitoring is a simple indirect method that is used to estimate both bioavailability and bioequivalence. However, the immunosuppressive effect of all these drugs is initiated by binding to receptors on the surface of lymphocytes, which leads to inhibition of cytokine production and proliferation of activated lymphocytes. Thus, it would be more advantageous to monitor the level and effect of these drugs at the site of action (bioequivalence), the lymphocyte. This report describes an assay of this type that was developed for monitoring transplant patients at one center. The assay is based on measuring drug levels in the cytoplasm of lymphocytes. It is quick and easy to perform (20 samples per hour), inexpensive, and reproducible. The between-run Coefficient of Variance (CV) is 5.4 and a within-run CV is 3.1. For this study, blood and lymphocyte drug levels in transplant patients were determined and correlated with graft function and clinical events (biopsy-proven rejection and/ or toxicity).

| Başkent Üniversitesi | Kütüphane | Açık Bilim Politikası | Açık Erişim Politikası | Rehber |

DSpace software copyright © 2002-2026 LYRASIS

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify