Browsing by Author "Koroglu, Mert"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item Comparing 1470-and 980-nm Diode Lasers for Endovenous Ablation Treatments(2015) Aktas, Aykut Recep; Celik, Orhan; Ozkan, Ugur; Cetin, Mustafa; Koroglu, Mert; Yilmaz, Sevda; Daphan, Birsen U.; Oguzkurt, Levent; 0000-0002-3506-2039; 25990260The purpose of this study was to compare the effectiveness of 1470- and 980-nm lasers with regard to power output, complications, recanalization rates, and treatment response. We prospectively evaluated the effectiveness of endovenous laser ablation (EVLA) in a total of 152 great and small saphenous veins from 96 patients. Lasers were randomly used based on the availability of the units. Patients were clinically evaluated for Clinical Etiologic Anatomic Pathophysiologic (CEAP) stage and examined with Doppler ultrasound. Treatment response was determined anatomically by occlusion of the vein and clinically by the change in the venous clinical severity score (VCSS). Seventy-eight of the saphenous veins underwent EVLA with a 980-nm laser and 74 underwent EVLA with a 1470-nm laser. Treatment response was (68) 87.2 % in the 980-nm group and (74) 100 % in the 1470-nm group (p = 0.004). The median VCSS decreased from 4 to 2 in the 980-nm group (p < 0.001) and from 8 to 2 (p < 0.001) in the 1470-nm group. At 1-year follow-up, seven veins treated with 980 nm and two veins treated with 1470 nm were recanalized (p = 0.16); the average linear endovenous energy density (LEED) was 83.9 (r, 55-100) J/cm and 58.5 (r, 45-115) J/cm, respectively (p < 0.001). Postoperative minor complications occurred in 23 (29.4 %) limbs in the 980-nm group and in 19 (25.6 %) limbs of the 1470-nm group (p = 0.73). EVLA with the 1470-nm laser have less energy deposition for occlusion and better treatment response.Item Long-term clinical and angiographic follow-up results of the dual-layer flow diverter device (FRED) for the treatment of intracranial aneurysms in a multicenter study(2021) Dinc, Hasan; Saatci, Isil; Oguz, Sukru; Baltacioglu, Feyyaz; Yildiz, Altan; Donmez, Halil; Belet, Umit; Onal, Baran; Andic, Cagatay; Koc, Osman; Kocak, Omer; Koroglu, Mert; Cetin, Mustafa; Cekirge, H. Saruhan; https://orcid.org/0000-0001-8581-8685; 33392735; AAM-3180-2021Purpose Our aim was to determine the long-term safety and efficacy of the Flow Re-Direction Endoluminal Device (FRED) in this multicenter study with prospective design. Materials-method This study included 136 consecutive patients with 155 aneurysms treated between March 2013 and June 2016 in 10 centers. Twenty-two (16.2%) patients presented with rupture of the index aneurysm. Large/giant aneurysms comprised 1/3 of the cohort. Adjuvant coil use during the treatment was 15.5%. The effectiveness measure in the study was the percentage of aneurysms with stable occlusion at follow-up. Results Vascular imaging follow-up was performed at least once in 131/136 (96.3%) patients with 148/155 (95.5%) aneurysms up to 75 months (mean: 37.3 months; median: 36 months according to latest follow-up), and 102/155(65.8%) aneurysms in 90/136 (66.2%) patients had >= 24-month control. According to the latest controls, the overall stable occlusion rate was 91.9% (95% CI, 87.5 to 96.3%). Three out of 148 aneurysms with follow-up were retreated (2%, 95% CI 0.0 to 4.3%). Adverse events were noted in 19/136 (14%, 95% CI, 9 to 21%) patients with a morbidity of 1.5% (95% CI, 0.0 to 3.5%). Mortality was 1/136 (0.7%, 95% CI, 0.02 to 2.2%) and was unrelated to aneurysm treatment. In-stent stenosis (ISS) was detected in 10/131 of the patients with follow-up (7.6%, 95% CI; 3.1 to 12.2%), only one being symptomatic. No adverse events have occurred in any of the patients with follow-up after 24 months, except the one resulting from ISS. Conclusion In the treatment of cerebral aneurysms which were candidates for flow diversion technique, this study showed long-term efficacy of FRED with good safety and occlusion rates.