Repository logo
Communities & Collections
All of DSpace
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Emiroğlu, Remzi"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • Thumbnail Image
    Item
    Tromboze greft arteryovenöz fistülü olan hastalarda arrow-trerotola cihazi ile perküten mekanik trombektomi
    (Tanısal ve Girişimsel Radyoloji ,9 (3) ,371-376, 2003) Fırat, Ali; Aytekin, Cüneyt; Boyvat, Fatih; Emiroğlu, Remzi; Haberal, Mehmet
    Tromboze arteryovenöz fistülü olan hemodiyaliz hastalarında perkütan mekanik trombektomi işleminde kullanılan Arrow-Trerotola cihazının etkinliğinin ve güvenilirliğinin araştırılması. GEREÇ VE YÖNTEM Greft fistül oklüzyonu olan 10 hastaya Arrow-Trerotola cihazı ile perkütan mekanik trombektomi işlemi yapıldı. 10 hastaya toplam 13 kez işlem uyglandı. Teknik başarı, komplikasyonlar, primer ve sekonder açık kalım oranları değerlendirildi. Teknik başarı oranı %84 idi (13 işlemin 11'inde). Hastaların hiç birisinde majör komplikasyon izlenmedi. Ortalama takip süresi 8,5 ay idi. Yedi hastada greft fistüller hala patenttir. Bu 7 hastanın 3'ünde patensinin devamı için ek işlemler uygulandı. Üç aylık primer ve sekonder açık kalım oranları sırasıyla %66 ve %77 olarak hesaplandı. SONUÇ Arrow-Trerotola perkütan mekanik trombektomi cihazı tromboze hemodiyaliz greftlerinin tedavisinde kullanılan etkili bir yöntemdir. To assess the safety and efficacy of the Arrow-Trerotola percutaneous thrombectomy device in the treatment of thrombosed hemodialysis access grafts in dialysis patients. MATERIALS AND METHODS: Ten patients with graft fistula occlusion underwent mechanical thrombectomy with Arrow-Trerotola percutaneous thrombectomy device. Thirteen trombectomy procedures were performed in ten patients. Technical success, complications, primary and secondary patency rates were noted. RESULTS: The technical success rate was 84% (11 of 13 procedures). There were no major complications. The mean follow-up period was 8,5 months. The graft fistula are still functional in seven patients. In 3 of 7 patients, additional procedures were needed for patency. The 3-month primary and secondary patency rates were 66% and 77% respectively. CONCLUSION: Percutaneous mechanical thrombectomy with the Arrow-Trerotola device is an effective method for the treatment of the thrombosed hemodialysis grafts.

| Başkent Üniversitesi | Kütüphane | Açık Bilim Politikası | Açık Erişim Politikası | Rehber |

DSpace software copyright © 2002-2026 LYRASIS

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify