Browsing by Author "Asena, Leyla"
Now showing 1 - 20 of 34
- Results Per Page
- Sort Options
Item Atypical Intrapapillary Hemorrhage in a Patient with Glaucoma(2015) Gungor, Sirel Gur; Ozisik, Gulce Gokgoz; Akman, Ahmet; Asena, LeylaA 73-year-old man presented for routine follow-up. There were primary open-angle glaucoma, diabetes mellitus, and usage of acetylsalicylic acid in patient's history. Dilated fundus examination demonstrated cup hemorrhage in the right eye. Because of the progression of the superotemporal retinal nerve fiber layer defect in the last seven months, we think that the disk hemorrhage could be associated with glaucoma. (Turk J Ophthalmol 2015; 45: 77-8)Item Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation(2016) Gungor, Sirel Gur; Akman, Ahmet; Asena, Leyla; Aksoy, Mustafa; Sezenoz, Almila Sarıgul; 0000-0002-6848-203X; 0000-0002-7030-5454; 0000-0001-6178-8362; 0000-0003-1513-7686; 28050320; E-5914-2016; AAJ-4860-2021; AAD-5967-2021Objectives: To compare anterior chamber depth (ACD) changes after phacoemulsification surgery in patients with pseudoexfoliation syndrome (PEX) and normal patients using an anterior segment imaging method. Another aim of this study was to evaluate the effect of these changes on the accuracy of intraocular lens (IOL) power calculation and postoperative refraction. Materials and Methods: Twenty-two eyes of 22 patients with PEX and 30 eyes of 30 normal patients who underwent uneventful phacoemulsification surgery and IOL implantation were included in the study. The ACD of all patients was evaluated preoperatively and at 3 months postoperatively with the ALLEGRO Oculyzer (WaveLight (R) Oculyzer (TM) II, Alcon, Novartis)-Scheimpflug imaging system. Results: The postoperative mean ACD values were significantly larger than the preoperative ACD values in both groups (p < 0.001 for both groups). The pre- to postoperative change in ACD was 0.46 +/- 0.3 mm in the PEX group, which was a larger change than seen in the normal patients (0.12 +/- 0.1 mm) (p = 0.04). The mean absolute errors (MAE) calculated with different IOL formulas (SRK/T, Haigis, Hoffer and Holladay 1 formulas) were comparable and no statistically significant difference was observed between the two groups (p = 0.21). Conclusion: Phacoemulsification induces more significant ACD changes in patients with PEX compared to normal patients. However, the MAE did not differ significantly between the groups.Item Changes in ocular biometric parameters after renal transplantation(2020) Aksoy, Mustafa; Asena, Leyla; Gungor, Sirel Gur; Soy, Ebru H. Ayvazoglu; Akman, Ahmet; Haberal, Mehmet; 0000-0002-3462-7632; 0000-0002-0993-9917; 0000-0001-6178-8362; 0000-0002-6848-203X; 0000-0003-1513-7686; 32415655; AAJ-8097-2021; AAC-5566-2019; E-5914-2016; AAD-5967-2021Purpose This study aimed to investigate the changes in postoperative ocular biometric parameters in end-stage renal disease patients who underwent renal transplantation. Material and methods This retrospective study included a total of 33 eyes of 33 patients. The ocular biometric measurements which were evaluated were axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), corneal keratometry (K1 and K2), degree of astigmatism, lens thickness (LT), and intraocular pressure (IOP). Refractive prediction error (RE) was calculated before and after renal transplantation using the same diopter (D) for intraocular lens (IOL) power calculation and evaluated for potential cataract surgery. Results The study included 15 male (45%) and 18 female (55%) patients. Mean patient age was 31.55 +/- 8.24 (range: 18-49 years). In the comparison of preoperative and 1-month postoperative measurements, there was a statistically significant difference in AL, LT, ACD, and CCT (p < 0.001). There was no statistically significant difference between K1, K2, and astigmatism measurements (p = 0.72; p = 0.35; p = 0.62, respectively). There was no statistically significant difference in RE (p = 0.61-Holladay 2). Conclusion While renal transplantation surgery does not lead to significant changes in astigmatism, predicted refractive error, corneal keratometry, or intraocular pressure, it causes significant decrease in axial length, lens thickness, and central corneal thickness and significant increase in anterior chamber depth. However, these changes do not result in significant changes in IOL power calculation in planned cataract surgery.Item CHANGES IN OCULAR BIOMETRIC PARAMETERS AFTER RENAL TRANSPLANTATION(2020) Aksoy, Mustafa; Asena, Leyla; Gungor, Sirel Gur; Soy, Ebru H. Ayvazoglu; Haberal, Mehmet A.Item Clinical outcomes of deep anterior lamellar keratoplasty (DALK) in keratoconus patients.(2019) Altinors, Dilek Dursun; Asena, Leyla; Oto, SibelItem Clinical Outcomes of Scleral Misa Lenses for Visual Rehabilitation in Patients with Pellucid Marginal Degeneration(2016) Asena, Leyla; Altinors, Dilek Dursun; 0000-0002-6848-203X; 0000-0001-5223-0279; 27432029; E-5914-2016; AAK-8077-2021Purpose: To report the clinical outcomes of scleral Misa((R)) lenses (Microlens Contactlens Technolgy, Arnhem, Netherlands) for visual rehabilitation in patients with pellucid marginal degeneration (PMD). Mehods: In this prospective interventional case series, 24 eyes of 12 PMD patients were fitted with scleral Misa((R)) lenses. Patients were followed regularly for continuous daily wearing time (CDWT), contact lens handling issues, Visual acuity, and any subjective or objective contact lens related complications. Results: The mean patient age was 35.0 +/- 13.8 years (range, 23-47 years). The average length of follow-up was 14.1 +/- 3.7 months (range, 8.5-18 months). All eyes were fit with mini Misa((R)) scleral lenses with a diameter of 16.5 or 17 mm. The mean Snellen best-corrected visual acuity (BCVA) before scleral lenses with spectacle correction was 0.42 +/- 0.15 (range, 0.2-0.6). With scleral lenses, mean BCVA was 0.75 +/- 0.15 (range, 0.5-0.9), (p = 0.003) with a mean gain of 3.3 lines of BCVA. More than half (16 eyes, 67%) reported wearing theirscleral lenses for 8 h or more on a daily basis. Three patients (6 eyes, 25%) abandoned scleral lens wear. Patients who abandoned the scleral lens wear tended to have a better spectacle corrected visual acuity and less gain of lines. Conclusions: Scleral lenses can be used succesfully in patients with PMD who are intolerant to other types of contact lenses. Patients who have a low spectacle BCVA and a higher gain of visual acuity with scleral lenses are good candidates for scleral lens use. (C) 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.Item Comparison of Keratometric Measurements Obtained by the Verion Image Guided System with Optical Biometry and Auto-Keratorefractometer(2017) Asena, Leyla; Gungor, Sirel Gur; Akman, Ahmet; 0000-0002-6848-203X; 0000-0001-6178-8362; 27271763; E-5914-2016; AAD-5967-2021The aim of this study was to compare the keratometric measurements of Verion Image Guided System with an optical biometer (Zeiss IOLMaster 500, Carl Zeiss Meditec, Jena, Germany) and an automated keratorefractometer (AKR) (Topcon KR-8900, Topcon, Japan). In this prospective clinical trial, the right eyes of 52 patients with cataract were examined (mean age 62.25 +/- 12.16 years). The measurements were taken by the three systems in a random order. Keratometric data, magnitude of astigmatism, and astigmatic axis measurements from all three instruments were compared. The results were evaluated using, intraclass correlation coefficients (ICC), Bland-Altman plots, and paired samples t tests. The mean flat/steep K of Verion, IOLMaster, and AKR were 43.22 +/- 1.38D/44.23 +/- 1.46D, 43.07 +/- 1.26D/44.05 +/- 1.34D, and 43.07 +/- 1.31D/43.89 +/- 1.42D, respectively. Flat K readings of Verion were higher than IOLMaster and AKR (p < 0.05 for both). Steep K readings were different for all three (p < 0.05). The magnitude of astigmatism by Verion and IOLMaster were 0.98 +/- 0.65D and 0.98 +/- 0.59D (p = 0.88). The mean astigmatism measured by the AKR was 0.82 +/- 0.62D, less than the other two instruments (p < 0.001). Astigmatic axis measurements of Verion and AKR differed < 10A degrees in 38, between 10A degrees and 20A degrees in 5, and > 20A degrees in 9 eyes; the same difference was 30, 11, and 11 eyes, respectively, between Verion and IOLMaster. Although, keratometric and astigmatic results obtained from Verion were not completely interchangeable with IOLMaster and AKR, especially the agreement between Verion and IOLMaster was excellent with ICCs close to one. However, there were pronounced astigmatic axis measurement differences between three instruments.Item Comparison of Keratometry Obtained by a Swept Source OCT-Based Biometer with a Standard Optical Biometer and Scheimpflug Imaging(2018) Asena, Leyla; Akman, Ahmet; Gungor, Sirel Gur; Altinors, Dilek Dursun; 0000-0001-5223-0279; 0000-0002-6848-203X; 0000-0001-6178-8362; 29630418; AAK-8077-2021; E-5914-2016; AAD-5967-2021Purpose: To assess agreement of a swept source-optical coherence tomography (SS-OCT) based Biometer with a standard IOLMaster device and Scheimpflug Imaging (SI) to acquire keratometric measurements in cataract patients. Methods: In this prospective comparative study, 101 eyes of 101 cataract surgery candidates, aged 24-81years, were sequentially examined using three devices. Keratometry values at the flat (K1) and steep (K2) axis, mean corneal power (Km) and magnitude of corneal astigmatism as well as J0 and J45 vectoral components of astigmatism obtained with the SS-OCT based biometer (IOLMaster 700) were compared with those obtained with the IOLMaster 500 and SI. The agreement between measurements was evaluated by the Bland-Altman method, intraclass correlation coefficients (ICCs) and repeated-measures analysis of variance. Results: Mean K1 values from the three devices were similar (p=0.09). Mean K2 and Km values of IOLMaster 700 were higher than SI and lower than IOLMaster 500 (p=0.04 for K2 and p=0.02 for Km). There was a strong correlation between K1, K2, Km and magnitude of astigmatism obtained with all devices (r >= 0.80 and p<0.01). The 95% limits of agreement (LoA) width for each keratometric value were highest for the comparison between IOLMaster 500 and SI and lowest for the comparison between IOLMaster 700 and 500. The mean differences (width of 95% LoA) for J0 and J45 vectoral components were 0.005 (2.19) and 0.12 (2.92) for the measurements obtained by IOLMaster 700 vs IOLMaster 500 and 0.06 (1.79) and 0.02 (1.58) for the measurements obtained by IOLMaster 700 vs SI, respectively. Conclusions: With ICCs close to 1, the agreement between all devices was excellent for keratometric measurements. Mean K2, Km and astigmatism measurements from IOLMaster 700 were lower than IOLMaster 500 and higher than SI. However, the differences were quite small and are not expected to affect the final IOL power.Item Comparison of ocular discomfort after three different epithelial debridement techniques for corneal collagen cross-linking in keratoconus treatment(2021) Alkayid, Hosamadden; Asena, Leyla; Yuce, Aslihan; Colak, Meric Yavuz; Altinors, Dilek Dursun; 34250443Purpose: To compare the severity and duration of ocular discomfort after three different epithelial debridement techniques for corneal collagen cross-linking in the treatment of keratoconus. Methods: Fifty-five patients (65 eyes) known to have keratoconus were enrolled in this retrospective study. The eyes were divided into three groups based on the technique used for epithelial debridement for corneal collagen cross-linking procedure; excimer laser transepithelial phototherapeutic keratectomy was used in group 1 (18 eyes), alcohol-assisted epithelial removal was used in group 2 (27 eyes), and mechanical epithelial debridement was used in group 3 (20 eyes). Preoperative and postoperative (third month) best-corrected visual acuity (BCVA) using Snellen chart, objective refraction, and keratometry results were recorded. The results of the questionnaire obtained from the patient's medical records were reviewed regarding their subjective evaluation of postoperative symptoms including foreign body sensation, tearing, photophobia, and burning at the end of the first postoperative week. Paired-samples t test was used to compare preoperative and postoperative clinical findings. One-way analysis of variance (ANOVA) was used to analyze the differences between three independent groups. Results: BCVA improved from 0.51 +/- 0.27 to 0.58 +/- 0.21 (p = 0.05). Objective mean spherical and cylindrical refraction decreased from -5.08 +/- 2.78D to -4.46 +/- 2.91D (p = 0.22) and from -3.45 +/- 2.73D to -3.03 +/- 1.97D (p = 0.25). Mean maximum keratometry reading (K-max) decreased from 57.63 +/- 4.73D to 56.13 +/- 4.47D (p = 0.001). The mean score for foreign body sensation was the highest in group 3 (4.50 +/- 0.53) and the lowest in group 1 (2.10 +/- 1.85) (p = 0.01). The mean scores for tearing, photophobia, and burning sensation were comparable in three groups (p = 0.84, p = 0.13, and p = 0.61, respectively). The duration of photophobia was the shortest in group 1 (1.50 +/- 2.37 days), followed by group 3 (2.00 +/- 1.31 days) and group 2 (4.00 +/- 1.83 days) (p = 0.04). Conclusions: The severity and duration of adverse subjective symptoms during the first postoperative week after corneal collagen cross-linking appear to be milder with epithelial debridement using excimer laser transepithelial technique compared with -assisted debridement and mechanical debridement.Item Comparison of refractive outcomes using Scheimpflug Holladay equivalent keratometry or IOLMaster 700 keratometry for IOL power calculation(2021) Aksoy, Mustafa; Asena, Leyla; Gungor, Sirel Gur; Kucukoduk, Ali; Akman, Ahmet; 0000-0001-8024-4758; 33733281Purpose This study aims to compare postoperative refractive error results using Pentacam (Oculus Optikgerate GmbH) Holladay equivalent keratometry readings (EKR) or IOLMaster 700 (Carl Zeiss Meditec AG) keratometry (K) values in IOL power calculation. Material and methods This retrospective study included 54 eyes of 31 patients who underwent cataract surgery. Preoperative biometric measurements of all patients were obtained using IOLMaster 700 followed by Pentacam measurements. IOLMaster 700 K measurements on horizontal (K1) and vertical (K2) axes and EKR measurements on 2 mm (EKR2mm), 3 mm (EKR3mm) and 4.5 mm (EKR4.5 mm) corneal zones were recorded. EKR4.5 mm value and IOLMaster 700 K values were used in Holladay-II, SRK/T, Haigis, and Hoffer-Q formulas to calculate predictive refractive error (PRE). Absolute refractive error (ARE) was calculated as the absolute difference between actual postoperative refractive error (APRE) and PRE values. Results Mean age was 72.2 +/- 8.3 (51-87) years and mean IOL power was 21.5 +/- 2.9 D (18-23 D). There was no significant difference between PRE values when IOLMaster 700 K measurements and EKR4.5 mm K measurements were used in Holladay-II, SRK/T, Haigis, and Hoffer-Q formulas (p = 0.571, p = 0.833, p = 0.165, p = 0.347, respectively). There was no significant difference between APRE and ARE values (p = 0.124). According to mean ARE results, the closest estimate was achieved when the IOLMaster 700 K values were used in the Holladay-II formula (p = 0.271). Conclusion IOLMaster 700 K measurement and Pentacam EKR4.5 mm measurements can be used interchangeably. IOLMaster 700 K values yielded the most predictive measurement of the refractive result using the Holladay-II formula.Item Comparison of Visual Performance and Quality of Life with A New Nondiffractive EDOF Intraocular Lens and A Trifocal Intraocular Lens(2023) Asena, Leyla; Dogan, Irem Kirci; Oto, Sibel; Altinors, Dilek Dursun; 0000-0003-0171-4200; 0000-0002-6848-203X; 0000-0002-5574-7318; 36700928; AAJ-4668-2021; E-5914-2016Purpose: To compare visual performance and quality of life (QoL) following bilateral implantation of a new nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) and a trifocal IOL. Setting: Department of Ophthalmology, Baskent University Faculty of Medicine, Ankara, Turkey. Design: Prospective comparative interventional case series. Methods: 104 eyes of 52 patients with cataract, bilaterally implanted with a nondiffractive EDOF IOL or a trifocal IOL, were included. Outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), distance corrected intermediate visual acuity and distance corrected near visual acuity, defocus curves, QoL (Visual Function Index 14), quality of vision (Quality of Vision [QoV] index), contrast sensitivity (Pelli-Robson chart), and binocular reading speed. Results: Twenty-six patients were included in each group. The UDVA and CDVA were better in the EDOF group (0.05 +/- 0.04 and 0.01 +/- 0.04) than the trifocal group (0.13 +/- 0.06 and 0.11 +/- 0.07) (P=.02 and .01). Defocus curves showed that visual acuity was better with the EDOF IOL for vergences at 0.00, -0.50, and -1.00 and better with the trifocal IOL for vergences at -2.50, -3.00, -3.50, and -4.00. Contrast sensitivity scores were similar with both IOLs (P=.12). The overall mean QoL scores were lower in the EDOF group, indicating a better QoL (P=.04). The QoV was better in the EDOF group with significantly less glare, halos, and blurry vision (P<.01). Conclusions: The EDOF IOL performed better at distance, and the trifocal IOL performed better at near. Overall QoL and quality of vision were better with the EDOF IOL. Copyright (c) 2023 Published by Wolters Kluwer on behalf of ASCRS and ESCRSItem Customizing Illumination by the Operating Microscope Aids the Visualization of DMEK Grafts(2018) Altinors, Dilek Dursun; Asena, Leyla; Yilmaz, Gursel; Oto, Sibel; 0000-0001-5223-0279; 0000-0002-2589-7294; 0000-0003-0171-4200; AAK-8077-2021; AAK-6987-2021; AAJ-4668-2021Item Descemet Membrane Endothelial Keratoplasty: Outcomes in the First Year of Experience(2018) Altinors, Dilek D.; Asena, Leyla; 0000-0001-5223-0279; 0000-0002-6848-203X; 29528002; AAK-8077-2021; E-5914-2016Objectives: We aimed to report the clinical outcomes of Descemet membrane endothelial keratoplasty in our first year of experience. Materials and Methods: Patients who underwent Descemet membrane endothelial keratoplasty at the Baskent University Faculty of Medicine, Department of Ophthalmology, between 2015 and 2016 were included in the study. Patient demographics, cause of endothelial dysfunction, best-corrected visual acuity, central corneal thickness, graft survival, follow-up duration, and intraoperative and postoperative complications were recorded. Results: Five eyes of 5 patients (4 female, 1 male) with a mean age of 53.4 +/- 12.7 years were included. Cause of endothelial dysfunction included corneal endothelial dystrophy in 3 patients, pseudophakic bullous keratopathy in 1 patient, and endothelial graft failure after previous penetrating keratoplasty in 1 patient. Pre-stripped Descemet membranes obtained from the Ankara State Hospital Eye Bank were used. Mean duration of postoperative follow-up was 7.4 +/- 3.7 months. Mean preoperative Snellen best-corrected visual acuity and central corneal thickness were 0.24 +/- 0.15 and 625.5 +/- 97.4 mu m. Mean best-corrected visual acuity increased to 0.67 +/- 0.26 (P = .02) in the first month and to 0.84 +/- 0.11 (P < .01) at the end of follow-up. Mean central corneal thickness decreased to 546.6 +/- 28.4 pm (P = .03). Graft detachment was observed in 1 patient on the first postoperative day, and it was reattached successfully by injection of air into the anterior chamber. There were no intra-operative complications. All corneas were clear at the end of follow-up. Conclusions: Descemet membrane endothelial keratoplasty provides a new and exciting option for endothelial transplant and has the potential to become the primary procedure for surgical management of Fuchs endothelial dystrophy and corneal endothelial disease. Rapid visual rehabilitation with few and manageable complications and good visual outcomes are the major advantages of this procedure.Item Descemet's Membrane Endothelial Keratoplasty (DMEK): 6-Month Clinical Outcomes(2018) Altinors, Dilek Dursun; Asena, Leyla; Yilmaz, Gursel; Oto, Sibel; 0000-0001-5223-0279; 0000-0002-2589-7294; 0000-0003-0171-4200; AAK-8077-2021; AAK-6987-2021; AAJ-4668-2021Item THE EFFECT OF CORNEAL TRANSPLANTATION ON VISUAL FUNCTION AND VISION-RELATED QUALITY OF LIFE(2020) Asena, Leyla; Altinors, Dilek Dursun; Oto, SibelItem Effect of Dry Eye on Scheimpflug Imaging of the Cornea and Elevation Data(2017) Asena, Leyla; Alnors, Dilek D.; Cezairlioglu, Sefik; Boluk, Sefer Oguen; https://orcid.org/0000-0002-6848-203X; 28576215; E-5914-2016Objective: To evaluate the effect of dry eye on Scheimpflug imaging of the cornea and elevation data. Design: Prospective observational study. Participants: Scheimpflug images of 50 patients with dry eye who were being tested for eligibility for corneal refractive surgery were screened. Twelve eyes of 12 patients with abnormal Belin/Ambrosio enhanced ectasia display (BAD) anterior elevation difference were included in the study. The patients had no history of contact lens wear or any other sign of ectasia. Methods: Peak central corneal densitometry value, corneal volume, pachymetry at the thinnest point, and BAD anterior elevation difference value at the centre of the 9 mm zone were recorded before and after 4 weeks of dry eye treatment. Measurements were compared with the Wilcoxon signed rank test. Results: The mean corneal peak densitometry and volume were similar before and after therapy (p = 0.465 and p = 0.441, respectively). The mean anterior elevation difference value at the centre of the 9 mm zone before treatment (6.67 +/- 1.72 mu m) was significantly higher than the mean post-treatment value (4.00 +/- 1.48 mu m) (p = 0.002). The mean pachymetry at the thinnest location after treatment (548 +/- 11.0) was significantly higher than the pretreatment value (538 +/- 8.5) (p = 0.027). Conclusions: BAD anterior elevation differences and pachymetric measurements may be affected by ocular surface or tear film abnormalities associated with dry eye disease. Repeated evaluations after treatment may reveal normal results.Item Effects of topical Coenzyme Q10, Xanthan Gum and Sodium Hyaluronate on corneal epithelial wound healing(2021) Asena, Leyla; Gokgoz, Gulsah; Helvacioglu, Fatma; Ozgun, Gonca; Deniz, Emine Ebru; Altinors, Dilek Dursun; 0000-0002-6848-203X; 0000-0002-4837-7937; 0000-0002-6026-0045; 34134604; E-5914-2016; AAY-7932-2021; AAH-8887-2021Background: The aim was to compare the effects of three different eye drops on corneal epithelial wound healing in an experimental model. Methods: Twenty-four eyes of 24 female BALB/c mice were included. A 2 mm central corneal epithelial defect was created. Topical Coenzyme Q10 + Vitamin E D-alpha-TPGS 4 x 1 was applied to Group A (n = 6), topical Sodium hyaluronate + Xanthan Gum + 0.3% Nethylmicine 4 x 1 to Group B (n = 6) and topical Sodium hyaluronate 4 x 1 to Group C (n = 6). Group D (n = 6) was the control group without treatment. Clinical scoring according to corneal fluorescein staining and histopathological evaluations was performed. Results: Clinical scores according to corneal fluorescein staining were similar in all groups on days 1 (p = 0.05), 2 (p = 0.15) and 3 (p = 0.62). Electron microscopy revealed disruption of intercellular junctions between corneal epithelial cells and intracellular vacuole formation in all groups except Group A. Corneal epithelial thickness and superficial epithelial microvillus arrangement were close to normal in Group A. Conclusion: Although there was no difference in clinical scores between groups, electron microscopy revealed a better organised epithelium with normal configuration of microvilli and less vacuolisation in Group AItem Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500(2016) Akman, Ahmet; Asena, Leyla; Gungor, Sirel Gur; 0000-0001-6178-8362; 0000-0002-6848-203X; 26674777; AAD-5967-2021; E-5914-2016Purpose To compare the measurements and failure rates obtained with a new swept source optical coherence tomography (OCT)-based biometry to IOLMaster 500. Setting Eye Clinic, Baskent University Faculty of Medicine, Ankara, Turkey. Design Observational cross-sectional study and evaluation of a new diagnostic technology. Methods 188 eyes of 101 subjects were included in the study. Measurements of axial length (AL), anterior chamber depth (ACD), corneal power (K1 and K2) and the measurement failure rate with the new Zeiss IOLMaster 700 were compared with those obtained with the IOLMaster 500. The results were evaluated using Bland-Altman analyses. The differences between both methods were assessed using the paired samples t test, and their correlation was evaluated by intraclass correlation coefficient (ICC). Results The mean age was 68.3212.71years and the male/female ratio was 29/72. The agreements between two devices were outstanding regarding AL (ICC=1.0), ACD (ICC=0.920), K1 (ICC=0.992) and K2 (ICC=0.989) values. IOLMaster 700 was able to measure ACD AL, K1 and K2 in all eyes within high-quality SD limits of the manufacturer. IOLMaster 500 was able to measure ACD in 175 eyes, whereas measurements were not possible in the remaining 13 eyes. AL measurements were not possible for 17 eyes with IOLMaster 500. Nine of these eyes had posterior subcapsular cataracts and eight had dense nuclear cataracts. Conclusions Although the agreement between the two devices was excellent, the IOLMaster 700 was more effective in obtaining biometric measurements in eyes with posterior subcapsular and dense nuclear cataracts.Item Evaluation Of Gap Formation For Different Adhesive Agents In Primary Teeth With Optical Coherence Tomography(EUROPEAN ORAL RESEARCH, 2024-05-23) Uyar, Didem Sakaryali; Asena, Leyla; Tirali, Resmiye EbruPurpose This study aimed to evaluate gap formation between the tooth surface and restorative material in terms of microleakage by using optical coherence tomography (OCT) for self-etch and selective-etch applications of two different universal and one self-etch adhesives. Materials and Methods Sixty non-caries, primary molar teeth were divided into six groups; self-etch and selective-etch application ways of two different universal and one self-etch adhesive systems (n:10). After Class-V cavities were prepared, every tooth was distributed randomly in groups to apply adhesion procedure and then, all cavities were restored with polyacid-modified composite resin. Microleakage was evaluated by measuring the gap between the tooth surface and restoration by a blind researcher with Image J Software from OCT images. During statistical analysis, the significance level was accepted as p<0.05. Results According to the statistical analysis of the measurements obtained by Image J Software, selective-etch groups showed less gap formation than self-etch groups for each tested adhesive (p<0.05), and self-etch adhesive without etching showed significantly highest gap formation among all groups (p<0.05). Conclusion Universal adhesives with a selective-etching step might be preferred over self-etch adhesives for long-lasting polyacid-modified composite resin restorations in primary teeth. However, obtained results should be considered with another prospective clinical study for long-term prognosis.Item Evaluation of quality of life after implantation of a new trifocal intraocular lens(2019) Akman, Ahmet; Asena, Leyla; Ozturk, Caner; Gungor, Sirel Gur; 0000-0001-6178-8362; 0000-0002-6848-203X; 30612749; E-5914-2016; AAD-5967-2021Purpose: To evaluate the vision-related quality of life (QOL) after implantation of a new trifocal intraocular lens (IOL), by using the National Eye Institute Visual Function Questionnaire-14 (VF-14 QOL questionnaire). Setting: Baskent University Faculty of Medicine, Department of Ophthalmology, Ankara, Turkey. Design: Prospective noncomparative case series. Methods: Consecutive patients who had a new trifocal IOL (Pan-Optix) bilaterally implanted were included in the study. The vision-related QOL was assessed 3 months after the surgery in the second eye. The VF-14 QOL questionnaire was used, with a grading scale of 0, no difficulty; 1, a little difficulty; 2, moderate difficulty; 3, quite difficult; 4, impossible to perform. A subgroup of 14 patients, with an interval of at least 3 months between the surgery in the first eye and the surgery in the fellow eye, were also interviewed 3 months after the monocular IOL implantation. In this subgroup, the QOL with monocular and binocular implantation was compared. Results: The study comprised 48 patients. Reading small print, driving at night, and doing fine handwork were the most difficult tasks to perform, with the mean values of the VF-14 QOL questionnaire being 0.94 +/- 0.81 (SD), 0.89 +/- 0.68, and 0.64 +/- 0.67, respectively. Binocular implantation was associated with improvement in vision-related QOL when compared with monocular implantation, with significant differences in doing fine handwork such as sewing (P = .02) and using a computer (P = .03). Conclusions: With mean values of 1.00 or lower for each question, the results of the VF-14 QOL questionnaire indicated that patients who have the new trifocal IOL bilaterally implanted have an overall high satisfaction rate and a high vision-related QOL. (C) 2018 ASCRS and ESCRS