Development Of An Electrochemical Sensor Based On Porous Molecularly Imprinted Polymer Via Photopolymerization For Detection Of Somatostatin In Pharmaceuticals And Human Serum

dc.contributor.authorOzkan, Ece
dc.contributor.authorCorman, Mehmet Emin
dc.contributor.authorNemutlu, Emirhan
dc.contributor.authorOzkan, Sibel A.
dc.contributor.authorKir, Sedef
dc.date.accessioned2022-12-21T06:46:01Z
dc.date.available2022-12-21T06:46:01Z
dc.date.issued2022
dc.description.abstractThis study applied a new methodology to create a porous molecularly imprinted material for the highly selective and sensitive recognition of somatostatin (SOM), a growth hormone inhibitor. N-methacryloyl-L-aspartic acid (MAAsp) was synthesized and used as a functional monomer to form a molecularly imprinted polymer (MIP) by photopolymerization method on a glassy carbon electrode (GCE). The MIP film was synthesized in the presence of 2-hydroxyethyl methacrylate (HEMA) and ethylene glycol dimethacrylate (EGDMA) to form P(HEMA-MAAsp)@MIP/GCE sensor. The characterization of P(HEMA-MAAsp)@MIP/GCE was investigated by Fourier Transform Infrared (FTIR) spectroscopy, Scanning Electron Microscopy (SEM), and Electrochemical Impedance Spectroscopy (EIS) techniques. Afterward, the porous P(HEMA-MAAsp)@MIP/ GCE was optimized with removal agent, removal time, and incubation time to achieve a better response for SOM. Under optimum conditions, the calibration curve of SOM on the P(HEMA-MAAsp)@MIP/GCE sensor was linear in the range of 10 fM and 100 fM. The limit of detection (LOD) and lower limit of quantification (LLOQ) were found as 0.175 fM and 0.584 fM, respectively. The analytical performance of the P(HEMAMAAsp)@MIP/GCE sensor was investigated by comparing the electrochemical reaction of MIP with nonimprinted polymer (NIP). The analytical performance of the developed sensor was proved by applying it to the pharmaceutical preparation and serum. The selectivity of the sensor was shown by examining the binding of Octreotide and Lanreotide, which are the synthetic analogs of the SOM. The developed P(HEMA-MAAsp) @MIP/GCE sensor, which is green and sustainable, exhibited high sensitivity and selectivity for SOM and is the first method reported to be used in the electroanalysis of SOM.en_US
dc.identifier.issn1572-6657en_US
dc.identifier.issue919en_US
dc.identifier.scopus2-s2.0-85132876117en_US
dc.identifier.urihttp://hdl.handle.net/11727/8382
dc.identifier.volume919en_US
dc.identifier.wos000829293100010en_US
dc.language.isoengen_US
dc.relation.isversionof10.1016/j.jelechem.2022.116554en_US
dc.relation.journalJOURNAL OF ELECTROANALYTICAL CHEMISTRYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergien_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectElectroanalysisen_US
dc.subjectMolecular imprinted polymeren_US
dc.subjectN -methacryloylen_US
dc.subjectL -aspartic aciden_US
dc.subjectSomatostatinen_US
dc.subjectPharmaceutical preparationen_US
dc.subjectHuman serumen_US
dc.titleDevelopment Of An Electrochemical Sensor Based On Porous Molecularly Imprinted Polymer Via Photopolymerization For Detection Of Somatostatin In Pharmaceuticals And Human Serumen_US
dc.typeArticleen_US

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: