Basit öğe kaydını göster

dc.contributor.authorKulah, Kivanc
dc.contributor.authorGulsahi, Ayse
dc.contributor.authorKamburoglu, Kivanc
dc.contributor.authorGeneci, Ferhat
dc.contributor.authorOcak, Mert
dc.contributor.authorCelik, H. Hamdi
dc.contributor.authorOzen, Tuncer
dc.date.accessioned2021-02-28T15:32:21Z
dc.date.available2021-02-28T15:32:21Z
dc.date.issued2019
dc.identifier.issn2212-4403en_US
dc.identifier.urihttp://hdl.handle.net/11727/5447
dc.description.abstractObjective. The aim of this study was to assess the trabecular microarchitecture of the maxilla by using cone beam computed tomography (CBCT) and micro-computed tomography (micro-CT) ex vivo. Study Design. Seventeen maxillary cadaver specimens were scanned by using micro-CT and CBCT devices. Samples were scanned with 2 CBCT devices at different voxel sizes (0.08, 0.125, and 0.160 mm for 3-D Accuitomo 170; 0.75 and 0.200 mm for Planmeca Promax 3-D Max). Morphometric parameters, such as bone volume/total volume (BV/TV) ratio, trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), trabecular number (Tb.N), and degree of anisotropy (DA) were assessed by using CTAnalyzer software. Bland-Altman limits of agreement and intraclass correlation coefficient (ICC) were performed to evaluate agreement between CBCT and micro-CT in consideration of measured morphometric parameters. Statistical significance was set at P < .05. Results. The BV/TV, Tb.Th, Tb.Sp, and DA values were higher for CBCT images compared with micro-CT images, whereas the Tb. N value was lower with CBCT images than with micro-CT images. The BV/TV and DA parameters showed the highest agreement between CBCT and micro-CT devices (ICC = 0.421 for BV/TV and ICC = 0.439 for DA; P < .01). Conclusions. The BV/TV and DA parameters measured on CBCT obtained at the smallest voxel size were found to be useful for the assessment of maxillary trabecular microstructure.en_US
dc.language.isoengen_US
dc.relation.isversionof10.1016/j.oooo.2018.11.014en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBONE-MINERAL DENSITYen_US
dc.subjectMORPHOMETRIC-ANALYSISen_US
dc.subjectACCURACYen_US
dc.subjectPARAMETERSen_US
dc.subjectCTen_US
dc.titleEvaluation of maxillary trabecular microstructure as an indicator of implant stability by using 2 cone beam computed tomography systems and micro-computed tomographyen_US
dc.typearticleen_US
dc.relation.journalORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGYen_US
dc.identifier.volume127en_US
dc.identifier.issue3en_US
dc.identifier.startpage247en_US
dc.identifier.endpage256en_US
dc.identifier.wos000458263100012en_US
dc.identifier.scopus2-s2.0-85059145708en_US
dc.contributor.pubmedID30595501en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergien_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster