dc.description.abstract | Background: To present our findings obtained from the treatment of wide-necked intracranial neurysms with flow diverter stents.
Patients and Methods: Intracranial aneurysms were determined in 19 patients (14 females, 5 males; mean age, 56.6 years) between May 2011 and June 2014, and the patients were treated using flow diverter stents. A total of 28 flow diverter stents, including 9 Silk and 19 Pipeline stents were used. Occlusion rates evaluated with computed tomography at the end of month 6 and digital subtraction angiography after one year, intraoperative success, morbidity and mortality rates were determined.
Results: A total of 20 endovascular interventions, including two interventions in two different aneurysms in one patient were performed in 19 patients. Flow diverter stents were successfully implemented for wide-necked aneurysms at a success rate of 100%. Coil treatment had previously been performed in four patients. Aneurysm occlusion rates were 77.2% at month 6 and 90.9% at the end of month 12.
Conclusion: The use of flow diverter stents is a reliable and effective method in the treatment of wide-necked intracranial aneurysms with high aneurysm occlusion, and low morbidity and mortality rates. | en_US |
dc.language.iso | eng | en_US |
dc.relation.isversionof | 10.5812/iranjradiol.55461 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Stent | en_US |
dc.subject | Aneurysm | en_US |
dc.subject | Coil | en_US |
dc.subject | Endovascular | en_US |
dc.subject | Intervention | en_US |
dc.title | The Efficacy of Flow Diverter Stents in the Treatment of Wide-Necked Intracranial Aneurysms | en_US |
dc.type | article | en_US |
dc.relation.journal | IRANIAN JOURNAL OF RADIOLOGY | en_US |
dc.identifier.volume | 14 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.wos | 000428031800011 | en_US |
dc.identifier.scopus | 2-s2.0-85044721994 | en_US |
dc.contributor.orcID | 0000-0002-9057-722X | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | en_US |
dc.contributor.researcherID | F-4230-2011 | en_US |
dc.contributor.researcherID | ABI-3856-2020 | en_US |