Basit öğe kaydını göster

dc.contributor.authorCiftci, Gozde
dc.contributor.authorSomay, Suphi Deniz
dc.contributor.authorOzcan, Isil
dc.contributor.authorOzcelik, Tuncer Burak
dc.contributor.authorYilmaz, Burak
dc.date.accessioned2024-04-04T11:15:59Z
dc.date.available2024-04-04T11:15:59Z
dc.date.issued2023
dc.identifier.issn0022-3913en_US
dc.identifier.urihttps://boris.unibe.ch/164911/1/1-s2.0-S0022391321006491-main.pdf
dc.identifier.urihttp://hdl.handle.net/11727/12003
dc.description.abstractStatement of problem. Long-term reports on 2-implant-retained overdentures having metal frameworks and bars containing distal attachments are scarce.Purpose. The purpose of this retrospective study was to evaluate prosthetic complications with 2-implant-retained mandibular overdentures with metal frameworks having either screw-or cement-retained cantilevered bars with distal attachments.Material and methods. Seventy-three edentulous study participants who had been treated with mandibular overdentures with 2 implants were included. The parameters assessed were acrylic resin fractures (base fracture, fracture at midline), debonding of teeth, opposing prosthesis fracture, need for relining or rebasing, abutment and bar screw loosening and fracture, ball or bar attachment or clip wear, fracture or detachment, bar fracture, and implant loss. Statistical analysis was performed by using the Mann-Whitney U test as the data were not normally distributed. The categorical variables between the groups were analyzed by using the Fisher exact test (alpha=.05).Results. Twenty-seven prostheses had a cement-retained bar, and 46 bars were screw-retained. Of 73 overdentures, 68 were metal-reinforced. The mean observation time was 5.9 years with a range between 2 and 12 years. The most common complication was wear of the Rhein 83 polymer attachment followed by bar screw loosening. The cumulative survival rate for overdentures was 91.9% at 6.8 years. The service life of cement-retained prostheses was significantly longer (P<.05). Bar, resin base, and mid-line fractures were only seen with cement-retained prostheses. The number of times an attachment change was required did not differ between cement-and screw-retained bars. Of 191 implants, 3 were lost, and the cumulative survival rate was 93.5% at 7.5 years. No significant difference was found between retention types in terms of implant loss (P>.05).Conclusions. Based on the participant population observed, the survival rates of 2-implant-retained mandibular overdentures and their implants in the medium term were high. Wear of the polymer attachment was commonly seen. Overdentures with cement-retained bars had bar or acrylic resin fractures. Mandibular 2-implant-retained overdentures with a screw-retained bar containing bilateral distal attachments had fewer prosthetic complications and high implant survival in the medium term.en_US
dc.language.isoengen_US
dc.relation.isversionof10.1016/j.prosdent.2021.11.016en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMULTICENTER CLINICAL-TRIALen_US
dc.subject3 TREATMENT MODALITIESen_US
dc.subjectQUALITY-OF-LIFEen_US
dc.subjectSUPPORTED OVERDENTURESen_US
dc.subjectFOLLOW-UPen_US
dc.subjectEDENTULOUS PATIENTSen_US
dc.subjectPROSTHODONTIC MAINTENANCEen_US
dc.subjectENDOSSEOUS IMPLANTSen_US
dc.subjectITI IMPLANTSen_US
dc.subjectSATISFACTIONen_US
dc.titleProsthetic Complications with Mandibular Bar-Retained Implant Overdentures Having Distal Attachments and Metal Frameworks: A 2-To 12-Year Retrospective Analysisen_US
dc.typearticleen_US
dc.relation.journalJOURNAL OF PROSTHETIC DENTISTRYen_US
dc.identifier.volume130en_US
dc.identifier.issue4en_US
dc.identifier.startpage573en_US
dc.identifier.endpage580en_US
dc.identifier.wos001106303600001en_US
dc.identifier.scopus2-s2.0-85122310882en_US
dc.identifier.eissn1097-6841en_US
dc.contributor.pubmedID34998584en_US
dc.contributor.orcID0000-0001-5685-4409en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergien_US
dc.contributor.researcherIDJJF-5618-2023en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster