Basit öğe kaydını göster

dc.contributor.authorErsoy, Ozgur
dc.contributor.authorGultekin, Bahadir
dc.contributor.authorOzkan, Murat
dc.contributor.authorAkkaya, Ilknur
dc.contributor.authorUmaroglu, Sevi
dc.contributor.authorSezgin, Atilla
dc.date.accessioned2023-11-15T13:27:30Z
dc.date.available2023-11-15T13:27:30Z
dc.date.issued2015
dc.identifier.issn1304-0855en_US
dc.identifier.urihttp://hdl.handle.net/11727/10859
dc.description.abstractObjectives: Red blood cell distribution width is a measure of the variability in the size of circulating erythrocytes, which is calculated by automated blood cell counters as part of a routine blood cell count analysis. Our aim was to examine whether continuous flow left ventricular assist devices affected red blood cell distribution width. Materials and Methods: Our study included 16 of 24 patients who received a HeartWare HVAD Pump (HeartWare Inc, Framingham, MA, USA) implant (continuous flow left ventricular assist device) between April 2012 and February 2015 at our institution. The mean age of the patients was 46.6 years. We compared patient erythrocyte, leucocyte, and platelet counts, hemoglobin and hematocrit levels, mean corpuscular volume, and red blood cell distribution width values before and 6 months after implant. Results: Hemoglobin level (P=.008), hematocrit level (P=.027), and mean corpuscular volume (P=.003) were significantly decreased; however, we observed no significant change in red blood cell distribution width. Conclusions: Although we did not find significant results in our group of patients with left ventricular assist device implant, a larger group of patients may show more significant results, and an increase in red blood cell distribution width can be used as an indicator of a negative prognosis in these patients.en_US
dc.language.isoengen_US
dc.relation.isversionof10.6002/ect.tdtd2015.P73en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectHeart failureen_US
dc.subjectBiomarkeren_US
dc.subjectLaboratory testsen_US
dc.subjectAnemiaen_US
dc.titleEffect of Left Ventricular Assist Devices on Red Blood Cell Distribution Widthen_US
dc.typearticleen_US
dc.relation.journalEXPERIMENTAL AND CLINICAL TRANSPLANTATIONen_US
dc.identifier.volume13en_US
dc.identifier.issueSupplement 3en_US
dc.identifier.startpage137en_US
dc.identifier.endpage139en_US
dc.identifier.wos000378800300036en_US
dc.identifier.scopus2-s2.0-84953873924en_US
dc.contributor.pubmedID26640934en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergien_US
dc.contributor.researcherIDABA-7388-2021en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster